Anaesthesia workstation PRIMUS - Excellent 2009

Brand: Dräger
Categories: Anesthesia


The Dräger Primus redefines anaesthesia workstation, serving as your personal assistant in modern healthcare settings. Featuring advanced monitoring capabilities, including a 12.1" TFT color display, it ensures real-time insights into patient status. With the E-Vent plus ventilator and various operating modes, it offers peak performance while accommodating diverse clinical needs. Its intuitive design, integrated power backup, and comprehensive alarm system guarantee uninterrupted patient care. From monitoring inspiratory concentrations to displaying graphical trends, the Primus optimizes clinical decision-making. With flexible connectivity options, including 3 x RS 232 ports, it ensures seamless integration into clinical workflows, enhancing efficiency and interoperability.

Offer Details

Appareil totalement reconditionné

Pour plus de détails, consultez nos équipes à contact@remma.fr

Description

Dräger Primus: Your Comprehensive Anaesthesia Assistant for Modern Healthcare Environments

The Dräger Primus stands as more than just an anaesthesia workstation; it's envisioned to be your personal anaesthesia assistant, meticulously crafted to meet the demands of modern healthcare environments. By blending time-honored design principles with cutting-edge technology, the Primus emerges as a comprehensive solution, adept at navigating the complexities of contemporary medical care.

As the number of critically ill patients within operating rooms continues to rise, the need for elevated standards in anaesthesia platforms becomes increasingly evident. With the inclusion of the E-Vent plus high-speed electronic piston ventilator, the Primus sets a new benchmark, offering peak flow rates akin to those found in ICU ventilators while eliminating the requirement for drive gas. An array of volume and pressure-oriented modes caters to diverse clinical scenarios, ensuring adaptability and efficacy in patient care. Moreover, advanced monitoring and ventilation mode packages further augment the system's capabilities, empowering clinicians with enhanced diagnostic tools.

In keeping with Dräger's commitment to intuitive design, the Primus adopts a familiar user interface and operational philosophy consistent across all Dräger medical devices. This standardized approach not only streamlines the learning curve for medical staff but also ensures seamless integration into existing workflows, minimizing disruptions and maximizing efficiency.

Central to the Primus's functionality is its expansive monitoring capabilities, facilitated by a spacious 12.1" TFT color display. Pulmonary function and ventilation parameters can be effortlessly monitored and configured to suit individual preferences, offering real-time insights into patient status. The system's open architecture design affords the flexibility to incorporate additional displays, expanding monitoring capabilities to encompass haemodynamic and other vital data points, further enriching clinical decision-making.

In pursuit of enhanced workflow efficiency, the Primus incorporates a suite of features designed to optimize operational processes. Automatic self-check capabilities mitigate the risk of equipment malfunctions, while open architecture and standard user interfaces simplify integration with existing systems. Flexible monitoring options empower caregivers to tailor their approach to patient care, fostering a more personalized and attentive healing environment. With a focus on cost reduction, time savings, and caregiver empowerment, the Primus enables healthcare professionals to channel their energies where they matter most – delivering exceptional patient care.

In addition to its robust design and functionality, the Dräger Primus boasts a weight of 115 kg (without vaporizers or cylinders), ensuring stability and durability in various clinical settings. With an integrated power backup system offering a minimum of 30 minutes and a typical duration of 90 minutes, depending on ventilation mode, the Primus provides uninterrupted support even during power outages, safeguarding patient care.

Operating modes encompass Manual, Spontaneous, Volume Mode (IPPV), and Pressure Mode (PCV), offering versatility to accommodate diverse patient needs. Optional modes such as Pressure Support (PS), Synchronized volume-controlled ventilation (SIMV), and Synchronized pressure-controlled ventilation further enhance the Primus's adaptability to clinical scenarios.

Comprehensive monitoring capabilities enable clinicians to assess key parameters essential for patient care. These include the monitoring of inspiratory and expiratory concentrations of O2, N2O, CO2, and anaesthetic agents such as Halothane, Isoflurane, Sevoflurane, and Desflurane. Minute volume (MV), tidal volume (VT), breathing frequency, peak pressure, plateau pressure, mean pressure, PEEP, and patient compliance (CPAT) are also monitored in real-time. Optional functionalities such as Functional oxygen saturation (SpO2) further augment the monitoring capabilities.

The Dräger Primus offers a comprehensive display of parameters, including waveforms displaying concentrations of CO2, O2, and anaesthetic agents, airway pressure, inspiratory and expiratory flow, and Plethysmogram. Bar graph displays of volumeter and tidal volume, as well as virtual flow tubes for O2, AIR, and N2O, enhance visualization. Graphical trends and numerical lists of measured values provide clinicians with comprehensive data for informed decision-making. The AutoSet feature for alarm limits ensures timely alerts for critical events, while the serial interface with 3 x RS 232 ports facilitates seamless data exchange and connectivity with external devices, further enhancing the Primus's functionality and interoperability in clinical settings.

Features

    • Integrated high-speed electronic piston ventilator (E-Vent plus).

    • Full range of volume and pressure-oriented modes.

    • Familiar user interface and operational philosophy.

    • Spacious 12.1" TFT color display for comprehensive monitoring.

    • Automatic self-check capabilities.

    • Open architecture design for flexibility and scalability.

    • Weight of 115 kg (without vaporizers or cylinders).

    • Integrated power backup system.

    • Operating modes: Manual, Spontaneous, Volume Mode (IPPV), Pressure Mode (PCV).

    • Optional modes: Pressure Support (PS), Synchronized volume-controlled ventilation (SIMV), Synchronized pressure-controlled ventilation.

    • Comprehensive monitoring of key parameters: O2, N2O, CO2 concentrations, anaesthetic agents, minute volume (MV), tidal volume (VT), breathing frequency, peak pressure, plateau pressure, mean pressure, PEEP, patient compliance (CPAT), Functional oxygen saturation (SpO2).

    • Display of parameters as waveforms: CO2, O2, and anaesthetic agents concentrations, airway pressure, inspiratory and expiratory flow, Plethysmogram.

    • Graphical trends and numerical lists of measured values.

    • AutoSet feature for alarm limits.

    • Serial interface with 3 x RS 232 ports for seamless data exchange and connectivity with external 

Technical Details

    • Weight: 115 kg (without vaporizers or cylinders)
    • Dimensions (H x W x D): 137 cm x 80 cm x 80 cm

    • Power: 200 W, typical operating voltage range of 100 to 240 V~, 45 to 65 Hz
    • Integrated Backup Power: At least 30 minutes, typical 90 minutes, depending on ventilation mode

    • E-Vent Plus Ventilator: Electronically driven and electronically controlled

Note: For more information, please refer to the PDF file.

Compatible Accessories

Attention : pour des informations sur les accessoires compatibles, veuillez consulter le PDF.

Explore

Servicing and Logistics

Remma and its partners provide you with serviced and configured equipment tailored to your needs. Receive your product at your facility with standard or express delivery, and an installation option, all through a single point of contact.

Warranty

Our 12/24-month warranty ensures the safety and reliability of your medical equipment throughout its lifespan.

Flexible Financing

Settle your medical equipment in up to 36 installments with our financing service or pay after delivery with Remma Facility.