• Medical Imaging Medical Imaging
  • Ophtalmology Ophtalmology
  • Operating Room Operating Room
  • Anesthesia Anesthesia
  • Laboratory Laboratory
  • Dental Equipment Dental Equipment
  • Gastroenterology Gastroenterology
  • Obstetrics and Gynecology Obstetrics and Gynecology
  • Cardiology Cardiology
  • Emergency Medicine Emergency Medicine
  • Comfort and Well-being Comfort and Well-being
  • Dermatology Dermatology
  • Healthcare Furniture Healthcare Furniture
  • Urology and Nephrology Urology and Nephrology
  • ENT ENT
  • Orthopaedics Orthopaedics
  • Physical Therapy and Rehabilitation Physical Therapy and Rehabilitation
  • Sterilization Sterilization
  • Intensive Care Intensive Care
  • Surgical Instruments Surgical Instruments

Bladder scanner BVI 9400 - Good

Brand: Verathon


The BVI 9400 Bladder Scanner, powered by NeuralHarmonics technology, offers rapid and accurate bladder volume measurement without invasive procedures. Its precision aiming and distinct scan modes cater to various patients, aiding in diagnoses like urinary retention and incontinence. The scanner prevents unnecessary catheterization, reducing patient trauma and CAUTI risk. It enhances healthcare efficiency with quick measurements, voice annotation, and an onboard printer for immediate records. Featuring an onboard tutorial and online calibration, it ensures optimal performance and reliability, revolutionizing medical diagnostics with its advanced features.

Description

Revolutionizing Medical Diagnostics: The BVI 9400 Bladder Scanner with NeuralHarmonics Technology

The BVI 9400 Bladder Scanner, equipped with NeuralHarmonics technology, represents a significant advancement in medical diagnostics. This portable, 3D ultrasound instrument offers a rapid, accurate, and noninvasive method for measuring urinary bladder volume and post-void residual (PVR). Its innovative design allows for seamless integration into clinical workflows, providing valuable insights into various urological conditions without the need for invasive procedures.

One of the standout features of the BVI 9400 is its ability to measure bladder volume noninvasively across a wide range of patients. This capability proves invaluable in assessing urinary retention and post-operative urinary retention (POUR), allowing healthcare professionals to make informed decisions regarding patient care and treatment pathways.

Moreover, the BVI 9400 plays a crucial role in evaluating common urological concerns, including but not limited to incontinence. By providing accurate measurements, it aids in differentiating between types of incontinence, thereby guiding clinicians in determining the most appropriate course of action for their patients.

Furthermore, the BVI 9400 serves as a valuable tool in the prevention of unnecessary catheterization. By accurately assessing bladder volume, it helps healthcare providers avoid catheterization when it's not warranted, thus reducing the risk of unnecessary trauma to patients and lowering the incidence of catheter-associated urinary tract infections (CAUTI).

In addition to its diagnostic capabilities, the BVI 9400 enhances the efficiency of healthcare professionals by streamlining processes and reducing costs. Its quick and accurate measurements save valuable staff time, allowing for more efficient patient care delivery and resource allocation within healthcare settings.

The BVI 9400 Bladder Scanner excels in providing precision aiming ability, enhancing the accuracy of bladder volume measurements. Whether using the console or the probe, healthcare professionals benefit from advanced targeting capabilities, allowing them to precisely locate the bladder for optimal scanning results. This precision aiming feature ensures that measurements are taken from the correct anatomical location, enhancing the reliability of the diagnostic data obtained.

Additionally, the BVI 9400 offers distinct scan modes tailored to the specific anatomical differences between men, women, and small children. By accommodating these variations, the scanner ensures accurate and reliable measurements across diverse patient demographics, enhancing its utility in clinical practice.

Voice annotation functionality further enhances the diagnostic process by allowing healthcare professionals to record valuable patient and exam data during scanning. This feature ensures that essential information is captured and retained, facilitating comprehensive patient assessments and continuity of care.

The inclusion of an onboard printer is another valuable feature of the BVI 9400, enabling healthcare providers to generate immediate patient records or documentation for reimbursement purposes. This capability streamlines administrative tasks and enhances workflow efficiency, ensuring that patient data is accurately documented and accessible when needed.

For staff training and proficiency, the BVI 9400 features an onboard video tutorial, providing users with comprehensive guidance on device operation and scanning techniques. This educational resource enhances user confidence and competency, ensuring optimal utilization of the bladder scanner within clinical settings.

Moreover, the BVI 9400 offers the convenience of online calibration via ScanPoint, allowing for seamless calibration adjustments to maintain the accuracy and reliability of measurements over time. This capability ensures that the device remains consistently calibrated, providing healthcare professionals with confidence in the accuracy of diagnostic results.

In summary, the BVI 9400 Bladder Scanner incorporates a range of advanced features to enhance precision, efficiency, and usability in clinical practice. From precision aiming and distinct scan modes to voice annotation and onboard training resources, the scanner is designed to optimize diagnostic accuracy, streamline workflow, and improve patient care outcomes.

Features

    • Rapid, accurate, and noninvasive measurement of urinary bladder volume and post-void residual (PVR)

    • Noninvasive bladder volume measurement across a wide range of patients

    • Assessment of urinary retention and post-operative urinary retention (POUR)

    • Evaluation of common urological concerns, including incontinence

    • Prevention of unnecessary catheterization

    • Reduction of catheter-associated urinary tract infections (CAUTI)

    • Differentiation between types of incontinence

    • Evaluation of the need for catheterization during intermittent catheterization

    • Precision aiming ability via Console or Probe

    • Distinct scan modes provided for men, women, and small children

    • Voice annotation for exams to ensure valuable patient/exam data is retained

    • Onboard printer for patient records or reimbursement

    • Onboard video tutorial to train staff

    • Calibration online via ScanPoint

Technical Details

    • Bladder Volume Range: 0 to 999 ml

    • Ultrasound Parameters:
      • Maximum ultrasound Ispta during a scan: ≤ 5.0 mW/cm2
      • Maximum ultrasound Isppa during a scan: ≤ 60.0 W/cm2
      • Maximum MI (Mechanical Index): 0.95 max
      • Transducer diameter: 13 mm (0.512 inches)
      • Transducer resonant frequency: 3.0 MHz and 1.74 MHz
      • Transducer bandwidth: 75% at 10 dB
      • Time from 3D scan initiation to result display: < 3 seconds

Attention: For more information, please refer to the PDF file.

Compatible Accessories

Attention: For information on compatible accessories, please refer to the PDF.

Explore

Servicing and Logistics

Remma and its partners provide you with serviced and configured equipment tailored to your needs. Receive your product at your facility with standard or express delivery, and an installation option, all through a single point of contact.

Warranty

Our 12/24-month warranty ensures the safety and reliability of your medical equipment throughout its lifespan.

Flexible Financing

Settle your medical equipment in up to 36 installments with our financing service or pay after delivery with Remma Facility.