• Medical Diagnostic Equipment
  • Surgical and Therapeutic Equipment
  • Medical Furniture
  • Laboratory Equipment
  • Cleaning and Sterilization

Catheter CF7-3-60 - Good



The ClosureFast™ RFA Catheter CF7-3-60 by Medtronic is a cutting-edge medical device designed for thermal vein closure using radiofrequency energy. This catheter is part of the ClosureFast™ RFA system, renowned for its ability to deliver precise and uniform heat to targeted veins, ensuring effective closure and relief from symptoms. With a 60 cm insertable length and a 3 cm heating element, it offers a minimally invasive, outpatient solution with reduced pain and quicker recovery compared to traditional treatments. 

Description

ClosureFast™ RFA Catheter CF7-3-60: Innovative Solution for Thermal Vein Closure

The ClosureFast™ RFA Catheter CF7-3-60 by Medtronic is a sophisticated medical device designed for thermal vein closure using radiofrequency energy. This catheter is part of the ClosureFast™ RFA system, known for its ability to deliver consistent and uniform heat to target veins, resulting in successful vein closure and symptom relief. The procedure is minimally invasive and performed on an outpatient basis, offering a modern alternative to traditional vein treatments.

The ClosureFast™ procedure uses radiofrequency energy to precisely heat and close the affected veins. This technique redirects blood flow to healthier veins, alleviating symptoms associated with venous insufficiency. The uniform heat application provided by the catheter ensures complete and effective closure of diseased veins.

Compared to conventional vein treatments, the ClosureFast™ catheter offers several advantages. It is associated with less pain and bruising than laser treatments, and the minimally invasive nature of the procedure results in a faster recovery time. Patients are required to wear compression stockings for at least one week after the procedure to support healing.

A key feature of the ClosureFast™ system is its patented segmental procedure, which ensures gap-free thermal ablation. The device's heating elements provide an overlap of 0.5 cm at each segment. This overlap eliminates gaps between treatment segments, leading to more effective and durable vein closure.

The ClosureFast™ CF7-3-60 catheter precisely heats a 3 cm segment of the vein in a single 20-second interval. The radiofrequency energy causes the target vein to shrink and collapse, creating a fibrotic seal that occludes the vessel. This process is crucial for achieving successful and lasting vein closure.

The ClosureFast™ CF7-3-60 catheter is provided sterile and is intended for single use only. Due to its design, the catheter cannot be adequately cleaned or sterilized for reuse, which helps prevent risks such as bio-incompatibility or infection. Each catheter is designed to ensure optimal performance and patient safety during the procedure.

The ClosureFast™ catheter is compatible with the ClosureRFG™ generator and the ClosureRFS™ stylet. The generator delivers the necessary radiofrequency energy to the catheter and stylet and features a controlled feedback mechanism to monitor and regulate intravascular heat parameters in real time.

After the procedure, patients are required to wear compression stockings to support vein closure and reduce swelling. The effective treatment of the ClosureFast™ system and minimal post-procedure discomfort contribute to a smooth recovery experience for patients.

The ClosureFast™ RFA Catheter CF7-3-60 by Medtronic represents a significant advancement in the treatment of diseased veins through radiofrequency thermal ablation technology. Designed to provide effective and durable vein closure, this device minimizes pain and bruising while promoting a rapid recovery compared to traditional laser treatments. Its robust construction and ability to deliver uniform heat ensure reliable and lasting results, while its single-use nature guarantees maximum patient safety.




Features

  • Uniform Heat Delivery: Ensures consistent and effective vein closure.
  • Patented Segmental Procedure: Provides gap-free thermal ablation.
  • Minimally Invasive: Results in less pain and bruising with faster recovery.
  • Precise Heating: Delivers targeted treatment with a 3 cm heating element.
  • Single Use: Ensures optimal performance and safety for each procedure.

Technical Details

  • Compatible Guidewire: 0.025"
  • Heating Element Overlap: 0.5 cm
  • Software Version: RFG3 1.11.0 or higher
  • Insertable Length: 60 cm
  • Default Target Temperature Setting: 120°C
  • Heating Element Diameter: 2.3 mm
  • Software Version: RFG2 4.0.0 or higher
  • Maximum Power Setting: 18 W
  • Heating Element Length: 3 cm
  • Introducer Sheath (minimum ID size): 7 F (2.3 mm)

Compatible Accessories

  • ClosureRFG™ Generator: Delivers the necessary radiofrequency energy for effective treatment.
  • ClosureRFS™ Stylet: Used for treating perforator and tributary veins.
  • Compression Stockings: Required for post-procedure care to support vein healing.

Explore

Servicing and Logistics

Remma and its partners provide you with serviced and configured equipment tailored to your needs. Receive your product at your facility with standard or express delivery, and an installation option, all through a single point of contact.

Warranty

Our 12/24-month warranty ensures the safety and reliability of your medical equipment throughout its lifespan.

Flexible Financing

Settle your medical equipment in up to 36 installments with our financing service or pay after delivery with Remma Facility.