Topcon CT-1P Computerized Tonometer: Innovative Design for Enhanced Efficiency and Comfort
The Topcon CT-1P computerized tonometer introduces a new level of style and compactness, making it more adaptable to various settings within the examination room. Its flexible control panel allows for versatile positioning, catering to different room layouts and preferences. Gone is the need for a control lever, as the CT-1P offers an innovative touch screen control panel, streamlining operation and enhancing user experience. Pairing it with the Topcon Kerato-Refractometer CT-1P, built with the same design concept, optimizes space utilization in your examination room.
This tonometer employs an air-puff mechanism designed to deliver a gentle puff of air, ensuring patient comfort while requiring minimal maintenance and cleaning. As a non-contact tonometer, the CT-1P is distinguished by its innovative approach and high-quality construction, offering reliable measurements without the need for physical contact with the eye.
Featuring simple and quick operation, the CT-1P provides fully automated measurements for both the right and left eyes. Its touch screen control panel simplifies user interaction, while additional measurement modes enhance versatility. The adjustable control panel can be positioned in any direction, maximizing flexibility and space efficiency. Despite its compact body, the CT-1P maintains reliable measurements, thanks to its new ergonomic optical head and headrest design. With stable IOP measurement ensured by the soft air-puff, and corneal thickness measurement for IOP compensation, the CT-1P delivers accurate and dependable results for comprehensive eye examinations.
The Topcon CT-1P computerized tonometer offers fully automated operation, setting a new standard in ease of use and efficiency with its touch screen interface. With just a simple touch at the center of the pupil on the intuitive touch screen control panel, the CT-1P automatically gathers information for both the right and left eyes without delay. This advanced automation eliminates the need for a control lever, enhancing the overall user experience and streamlining the examination process.
In addition to its automated operation, the CT-1P features an additional measurement mode designed to save time and minimize inconvenience. This mode continues measurements until the preset IOP measurement count is reached, reducing the need for manual intervention and ensuring comprehensive data collection. Moreover, the CT-1P can also be set to manual mode if required, providing flexibility to suit different clinical scenarios. Once the pupil position is detected, the CT-1P maintains automated alignment, requiring only the press of a button to initiate measurement.
The CT-1P's color touch screen control panel further enhances usability, allowing all operating procedures to be seamlessly executed with intuitive touch controls. The interface is designed for simplicity and clarity, with sophisticated buttons that provide an intuitive operator experience. With its rapid and effortless measurement of both eyes, the CT-1P simplifies the tonometry process, enabling clinicians to focus more effectively on patient care.
The Topcon CT-1P computerized tonometer boasts a flexible and space-saving layout, thanks to its adjustable touch screen control panel. Operators can position themselves anywhere around the patient, as the control panel can be oriented in various directions. Whether in a conventional setup, against a wall, or tucked into a corner, the CT-1P adapts to different examination room configurations, contributing to a more efficient use of space.
Its compact body further enhances versatility, allowing operators to support patients from multiple positions during measurements, even when manipulating the patient's eyelid. These unique design aspects promote both space-saving and flexible layout options within the eye examination room.
In terms of safety, the CT-1P incorporates innovative features designed for fully automated operation. It maintains a preset distance between the cornea and the nozzle, with visual and audible alerts if the proximity becomes too close, ensuring patient safety and minimizing the risk of injury. Additionally, the nozzle design helps prevent dust and debris from entering the chamber, reducing the need for frequent cleaning and maintenance.
Equipped with a built-in thermal printer, the CT-1P facilitates seamless documentation of measurements, automatically cutting paper at the end of each printout. The use of a soft air puff for measurement ensures patient comfort and compliance, with software controls regulating the air pressure for each individual eye.
The tonometer's compact and ergonomic design prioritizes patient comfort, with a fixation target positioned at a gentle downward angle and an improved chinrest design. This setup not only enhances patient experience but also facilitates better interaction between the operator and the patient.
Furthermore, the CT-1P offers connectivity options, allowing integration with Topcon Imaging and database software. This feature enables easy access to patient data, streamlining workflow and facilitating effective patient management.