Schiller CARDIOVIT AT-102 Electrocardiograph: High-Quality Signal Acquisition for Accurate and Reliable Cardiac Activity Assessments.
The CARDIOVIT AT-102 electrocardiograph is an advanced resting ECG system designed to meet the demands of routine clinical use in various settings such as medical practices, clinics, and emergency medicine facilities. Its intuitive operation, facilitated by direct function keys, makes it user-friendly and efficient for healthcare professionals. Additionally, the system's versatility is enhanced by optional software upgrades, allowing for seamless integration into ergometry or spirometry measuring stations, catering to a wider range of diagnostic needs.
One of the notable features of the CARDIOVIT AT-102 is its compatibility with hospital information systems (HIS), enabling the download of work lists for planned ECG recordings directly onto the device. This integration streamlines workflow management and enhances efficiency in clinical practice. Moreover, the system's integrated accumulator ensures mobile operation, providing flexibility and convenience for healthcare providers to perform ECG recordings anytime and anywhere.
The CARDIOVIT AT-102 comes equipped with SCHILLER measurement and interpretation software, tailored for both pediatric and adult patients. With 12-lead ECG analysis, this software delivers high-quality and reliable results, eliminating the need for compromises and serving as a valuable tool for obtaining clinically reliable second opinions. Furthermore, the inclusion of SCHILLER thrombolysis software (SCHILLER STP) empowers physicians in preclinical and emergency care settings by providing indications about the probability of acute cardiac ischemia or acute coronary syndrome (ACS), based on patient-specific factors such as medication, age, sex, and ECG data.
In addition to its comprehensive ECG analysis capabilities, the CARDIOVIT AT-102 offers full control over ergometry functions, including bike ergometers with or without blood pressure recording, and treadmills. Standard exercise protocols are pre-incorporated into the system and can be customized or adjusted according to specific patient requirements, ensuring flexibility and precision in diagnostic testing and monitoring.
The CARDIOVIT AT-102 goes above and beyond to meet the evolving needs of healthcare professionals, offering enhanced flexibility and efficiency in daily clinical practice. With the ability to connect a spirometer sensor, this versatile device seamlessly transforms into a pulmonary function test (PFT) device, expanding its capabilities to include the recording and analysis of flow-volume and volume-time curves, along with corresponding parameters. This integration allows for comprehensive respiratory assessments, empowering clinicians to gather valuable insights into lung function and respiratory health.
For added convenience and flexibility, the CARDIOVIT AT-102 is equipped with two options for flow sensors: the SP-250 disposable flow sensor, renowned for its optimal hygiene, and the reusable SP-260 sensor. This choice enables healthcare providers to select the sensor that best suits their specific needs and preferences, ensuring maximum versatility and usability in various clinical settings.
With a range of available programs, including slow and forced spirometry, maximum voluntary ventilation (MVV), and interpretation programs compliant with standards set by organizations such as the American Thoracic Society (ATS) or the European Respiratory Society (ERS), the CARDIOVIT AT-102 offers comprehensive respiratory diagnostic capabilities. These programs enable precise measurements of vital respiratory parameters, facilitating accurate diagnosis and monitoring of respiratory conditions.
Furthermore, the CARDIOVIT AT-102 features comprehensive network connectivity, providing seamless integration with the SCHILLER SEMA cardiology information system. This connectivity optimizes workflow management by streamlining data transfer and enhancing the unit's functionality. With network access, healthcare professionals can work more efficiently, collaborate effectively, and receive additional support for clinical decision-making, ultimately improving patient care and outcomes.
The optional SCHILLER Communication Module (SCM) enhances the functionality of the AT-102 electrocardiograph by facilitating seamless integration with the SEMA-200 Data Management System from SCHILLER. This integration optimizes workflow management and expands the device's capabilities, offering a comprehensive solution for data management and communication in healthcare settings.
With bi-directional communication capabilities, the SCM enables seamless interaction not only with the SEMA-200 system but also with Hospital Information Systems (HIS) and Electronic Medical Record (EMR) Systems. This connectivity can be established via LAN, WLAN, or a standard modem, providing flexibility and compatibility with existing infrastructure.
One of the key benefits of the SCM is its ability to retrieve patient demographics directly from the SEMA-200 system, streamlining the data entry process and minimizing the risk of errors. Additionally, the optional barcode reader further enhances efficiency by automating the entry of patient identifiers, ensuring accuracy and consistency in record-keeping.
The worklist function facilitates efficient ECG acquisition by allowing a list of orders, complete with patient demographics, to be downloaded directly to the device. This automated process creates a traceable closed-loop workflow from order entry to billing, improving efficiency and reducing administrative burden.
Furthermore, the transmission of recordings to the SEMA-200 data management system enables long-term archiving of data, with user-friendly search and editing tools for efficient management of patients and recordings. Standard interfaces via HL7, GDT, and XML further enhance interoperability, allowing the SEMA-200 system to seamlessly integrate with other components of the healthcare IT ecosystem, thus avoiding isolated information silos and promoting a cohesive data management strategy.