• Medical Diagnostic Equipment
  • Surgical and Therapeutic Equipment
  • Medical Furniture
  • Laboratory Equipment
  • Cleaning and Sterilization

Excimer Laser MEL 80 - Good

Brand: Zeiss


Unlock precision and efficiency with the ZEISS MEL 80 Excimer Laser. This state-of-the-art technology from ZEISS offers optimized ablation profiles, high-performance eye tracking, and an intuitive interface for superior vision correction. Designed with the latest advancements in mind, the MEL 80 ensures rapid recovery and individualized treatment, making it an ideal investment for eye care professionals. With streamlined procedures, reduced treatment times, and seamless integration with the VisuMax femtosecond system, this laser solution delivers exceptional results with minimal stress for both practitioners and patients.

Offer Details

ATTENTION: a Zeiss Refractive suite consisting of a Zeiss Visumax 500 femtosecond laser, and a MAL 80 Excimer unit.

Both devices were in use until Summer 2024,, they have been deinstalled by Zeiss technical team, brought back in the Zeiss Facilities and completely checked. They are in good working order.

 


Options :

optional installation service, spare parts and maintenance on site.

Description

Unlock Precision and Efficiency with ZEISS MEL 80: The Ultimate Excimer Laser Solution

Excimer excellence starts with ZEISS. Since 1846, the name ZEISS has stood for quality and precision in optics. In 1986, ZEISS unveiled the first excimer laser for refractive correction of the eye. Over the last 25 years, the company has been at the forefront of advances in laser vision correction.

Invest in the refractive excimer technology with the ZEISS MEL 80. This top-quality ZEISS product is designed to make the correction of vision defects more patient-friendly and individual while providing optimized ablation profiles for quality outcomes. All parameters of this modern work platform are oriented towards increasing efficiency, achieving optimum treatment results, and rapid recovery of vision. Key features include a high ablation rate and a high-performance eye tracker system.

The MEL 80 offers the best outlook for you and your patients. Tangible benefits for your daily work include the overall ergonomic design concept and the economical operation of the system. Reap the advantages of an investment that is forward-looking, practical, and profitable.

With ZEISS, simplicity meets advanced technology. With the MEL 80, take advantage of standardized treatment procedures for optimum results. The MEL 80 software has been specially developed for this robust and flexible workstation. The graphic user interface is clearly structured and takes you step-by-step through the treatment. A large number of other helpful features facilitate and support your work with the MEL 80, including the ergonomically designed workstation, the individually positionable monitor, and the integrated video camera.

Everything's under control with the MEL 80. An active 1 kHz eye tracker with excellent feedback times and an ultra-rapid IR camera provide exact positioning during the laser treatment. Thanks to automatic pupil recognition, you can adjust the desired centering point within seconds, including the limbus. If the center of the pupil shifts with relation to the limbus during ablation, the eye tracker compensates for this. In addition, no pupil-dilating medication and related waiting times are necessary prior to this treatment.

The faster the treatment, the lower the stress. The MEL 80 can significantly reduce the treatment duration for patients, offering numerous benefits. Firstly, the stromal bed is only open for a short period, minimizing dehydration and shortening the regeneration process. Secondly, the laser firing pattern is thermally optimized to achieve an ideal balance between ablation speed, tissue heating, and pulse energy. Patients only need to concentrate on the fixation light for a few seconds, reducing their stress levels. Practices also benefit from increased efficiency and patient throughput. Additionally, the Cone of Controlled Atmosphere (CCA+) plume removal system ensures consistent atmospheric conditions during treatment.

Equipped to outperform, the MEL 80 excimer laser is integrated seamlessly with the VisuMax femtosecond system. This combined use allows patients to experience surgery as an integrated process, eliminating unnecessary waiting periods and increasing treatment efficiency. These systems communicate with each other efficiently, enabling optimal practice management. The coordinated product portfolio, consisting of the MEL 80 excimer laser and VisuMax femtosecond system, offers an integrated solution from a single source. This solution not only enhances data flow efficiency but also allows for individualized patient treatments and expanded networking capabilities.

Precision in all facets, the VisuMax femtosecond system offers the creation of very accurate and smooth flaps in preparation for Femto-LASIK procedures. With its highly advanced laser technology and innovative optical design, the VisuMax ensures maximum cutting precision, efficiency, predictability, and patient comfort. Together with the MEL 80, it forms a well-matched duo for a whole range of customized laser treatments.

Features

    • High ablation rate

    • High-performance eye tracker system

    • Ergonomically designed workstation

    • Individually positionable monitor

    • Integrated video camera

    • Active 1 kHz eye tracker with excellent feedback times

    • Ultra-rapid IR camera

    • Cone of Controlled Atmosphere (CCA+) plume removal system

    • Seamless integration with the VisuMax femtosecond system

    • Standardized treatment procedures for optimum results

Technical Details

    • Laser Data
      • Type: ArF excimer laser
      • Wavelength: 193 nm
      • Frequency: 250 Hz
      • Targeting Diode: 650 nm (Class 1 laser)

    • Device Data
      • MEL 80 Weight: 290 kg, including gas bottle (not included)
      • Dimensions (Laser, L x W x H): 800 x 1550 x 1490 mm
      • Power Supply: 100 V AC; 50/60 Hz; 17.5 A - 120 V AC; 50/60 Hz; 14.6 A - 208, 220, 230, 240 V AC; 50/60 Hz; 7.9 A
      • Approval: CE marking in accordance with Directive 93/42/EEC concerning medical devices
      • Gas Supply: Integrated 10 L ArF-Premix bottle (not included)

    • Equipment
      • Active Eye Tracker: Infrared, pupil and limbus tracking, 1050 frames per second (fps)
      • Integrated CCA+ (Plume Removal System)
      • Spot Scanning Parameters

    • Beam Dimensions: 0.7 mm FWHM (Full width at half maximum), Gaussian beam profile

Attention: For more information, please refer to the PDF file.

Compatible Accessories

Attention: For information on compatible accessories, please refer to the PDF.

Explore

Servicing and Logistics

Remma and its partners provide you with serviced and configured equipment tailored to your needs. Receive your product at your facility with standard or express delivery, and an installation option, all through a single point of contact.

Warranty

Our 12/24-month warranty ensures the safety and reliability of your medical equipment throughout its lifespan.

Flexible Financing

Settle your medical equipment in up to 36 installments with our financing service or pay after delivery with Remma Facility.