• Medical Diagnostic Equipment
  • Surgical and Therapeutic Equipment
  • Medical Furniture
  • Laboratory Equipment
  • Cleaning and Sterilization

Fundus non-mydriatic Camera AFC-230 - Good 2007

Brand: Nidek


The NIDEK AFC-230 digital retinal fundus camera revolutionizes retinal screening with its innovative optical system and advanced features. As the world's first fully automatic non-mydriatic camera, it provides high-resolution imaging with fine gradation, enabling precise observation of the anterior eye. Its ergonomic design and USB 2.0 connectivity make it easy to use and facilitate rapid image transfer to a PC.

Description

NIDEK's AFC-230 Digital Retinal Camera: Revolutionary Innovation for Simplified Retinal Screening

NIDEK introduces the revolutionary non-mydriatic digital retinal camera AFC-230, integrating all the necessary features for simplified retinal screening. The customized features of the AFC-230 enhance the accuracy and efficiency of ophthalmological medical examinations.

High-Quality Retinal Imaging

With an innovative imaging optical system, the AFC-230 achieves high-resolution digital retinal imaging with fine gradation. This gradation allows clear and detailed visualization of the entire retinal image, from the bright optic disc to darker pathological areas. With significantly reduced noise, the system provides retinal photographs with minimal flash exposure, ensuring quick and effective examination of both eyes and reducing patient discomfort. Equipped with an advanced optical system and a large sensor, the AFC-230 delivers high-quality images with a true field of view of 45°.

The AFC-230 is the world's first fully automatic non-mydriatic camera, equipped with advanced auto-tracking, auto-focus, and auto-capture technology. The auto-tracking feature enables precise and easy alignment on the anterior corneal center, while auto-focus ensures optimal sharpness. Once the retina is in focus, the Auto Shot function provides high-quality imaging without the need for manual manipulation of the retina.

AFC-230 Features

Precise observation of the anterior eye before imaging

The AFC-230 features a 5.7-inch TFT LCD screen (640 x 480), in addition to the special optical system, CCD camera, and high-resolution monitor for observing the anterior eye. This allows precise confirmation of the anterior eye condition (such as ptosis, ingrown eyelashes, nystagmus, cataracts, corneal disorders, etc.), ensuring high-quality retinal photographs.

Flexible viewing angle

Without the need for an adapter, the AFC-230 can capture a detailed image of a smaller field of view with high quality using a 35mm overview in a 45º viewing angle.

Unique blink control function

With automatic blink detection, the AFC-230 automatically pauses photo capture when the patient blinks.

Anterior eye capture mode

By pressing the dedicated anterior eye capture button, the AFC-230 automatically switches to capture mode to provide a clear image of the anterior eye.

Smaller pupil capture mode

In addition to the regular minimum pupil diameter of ø4.0 mm, the AFC-230 can detect an even smaller pupil diameter - minimum of 3.7 mm. When the patient's pupil diameter is smaller than the standard 4.0 mm, the AFC-230 automatically switches to a mode suitable for the smaller diameter.

Stereo capture mode *

Stereo retinal imaging is also an available option.

* A stereo viewer is required (optional).

Fast image transfer to a computer

Connecting to a computer via USB 2.0 ensures quick and easy image transfer. Data can also be saved to an external electronic file system via NAVIS-Lite.

Ergonomic design for convenient use in low-light environments

Compact format

All essential features are integrated into this compact format, ensuring increased portability.

AFC-230 Features

Suited for photography professionals

The ergonomic arrangement of buttons, levers, and dials facilitates intuitive operation, even in low-light environments.

Various configuration options

Easily connectable to a laptop or PC via USB 2.0 interface.

Quick and easy software installation on a laptop or PC using NAVIS-Lite installer.

NAVIS-Lite software is available in standalone or examination station versions.

System requirements: Windows XP or later

Interconnection with other existing modules

Image files and XML files can be exported automatically or manually to a designated folder. XML files contain information linking patient data to image files, facilitating data export to NAVIS and other existing software modules.

DICOM connection (optional)

DICOM connection can be established. It is also possible to retrieve task lists from the HIS server.

High-performance retinal image classification system - NAVIS-Lite

Main features of NAVIS-Lite

Images imported automatically from the AFC-230 are sorted by patient name.

Simple support protocols are in place to display patient information.

The system integrates advanced imaging features, such as image processing, drawing, measurement, and panoramic capture for comprehensive analysis.

Zoom: Images can be zoomed in as desired.

Effects: Sharpness, Combination, Edge Enhancement.

Color control: Grayscale, RGB Contrast, Without Red, Channel Division, Color Inversion, Brightness, Contrast, Histogram, Gamma Control, Intensity Selection.

Rotation / Inversion: The image can be rotated or inverted at any angle.

Measurement: C/D ratio, Vertical height of disc, Vertical height of cup, Distance between two points, Selected area.

Drawing: Text or objects can be added to the image.

Flexible print layout display for patient reports.

Data backup function.

Easy image export.

Email function for sending a text message with image files.

Data can be transferred to a DICOM (Digital Imaging and Communications in Medicine) 3.0 compatible server (optional).

In summary, the AFC-230 offers a comprehensive and advanced solution for capturing and analyzing retinal images, with innovative features and extensive connectivity to meet the needs of healthcare professionals.

Features

    • High-Quality Retinal Imaging: Achieves high-resolution digital retinal imaging with fine gradation.
    • Cutting-Edge Technology: World's first fully automatic non-mydriatic camera with automatic tracking, autofocus, and auto-capture.
    • Precise Anterior Eye Observation: Incorporates a 5.7-inch TFT LCD screen for precise observation before photography.
    • Flexible Field of View: Allows detailed imaging of a smaller field of view using a 35mm overview in a 45º field of view.
    • Unique Blink Control: Automatically stops photography when the patient blinks.
    • Versatile Photography Modes:
    • Anterior Eye Photography Mode: Provides a clear photograph of the anterior eye.
    • Smaller Pupil Photography Mode: Automatically detects a smaller pupil diameter and adjusts the photography mode accordingly.
    • Stereo Photography Mode: Enables stereo retinal photography (requires optional stereo viewer).
    • High-Speed Image Transfer to PC: Connection to a PC via USB 2.0 for quick and easy image transfer.
    • Ergonomic Design: Compact body and ergonomic arrangement of buttons, lever, and dial for intuitive use even in a dark room.
    • Compatibility with NAVIS-Lite: Integration with NAVIS-Lite software for high-performance retinal image classification, including image processing, measurement, and panoramic imaging.
    • DICOM Connection (optional): Ability to connect to a DICOM-compatible server for standardized data exchange.

Technical Details

Wieght : 25 kg

Dimensions : 208 x 505 x 507 mm

Compatible Accessories

See PDF.

Explore

Servicing and Logistics

Remma and its partners provide you with serviced and configured equipment tailored to your needs. Receive your product at your facility with standard or express delivery, and an installation option, all through a single point of contact.

Warranty

Our 12/24-month warranty ensures the safety and reliability of your medical equipment throughout its lifespan.

Flexible Financing

Settle your medical equipment in up to 36 installments with our financing service or pay after delivery with Remma Facility.