• Medical Diagnostic Equipment
  • Surgical and Therapeutic Equipment
  • Medical Furniture
  • Laboratory Equipment
  • Cleaning and Sterilization
  • Spare Parts

HI97715C Photometer - Perfect Condition

The HI97715C from Hanna Instruments is a waterproof portable photometer designed for accurate measurement of ammonia (NH₃-N) in the mid-range. Ideal for environmental, industrial or mobile laboratory applications, it guarantees reliable results thanks to its narrow-band LED light source and silicon photometric cell. It is compatible with a case containing cuvettes, standard solutions, cleaning cloths and batteries, making it ideal for on-site use. Compact, robust and easy to use, this photometer can store up to 50 measurements and includes CAL CHECK and GLP functions to ensure traceability and accuracy.



Offer Details

HANNA HI97715C ammonia photometer with case, up to 10.0 mg/L New equipment in its original packaging HI97715C comes in a carrying case with 2 measuring cuvettes, plastic caps and lids, cleaning cloths, scissors and batteries. Range: 0.10 to 10.00 mg/L (NH₃-N) Resolution: 0.01 mg/L Accuracy at 25 °C: ±0.05 mg/L ±5% of reading Method: Adapted from the "ASTM Manual of Water and Environmental Technology, D1426-92" method, Nessler method Light source: LED with narrow bandpass filter 420 nm Light detector: Silicon photocell Batteries/lifespan: 3 x 1.5 V AA / > 800 measurements without backlighting On-demand memory: Up to 50 measurements for display recall Auto shut-off: After 15 minutes of non-use / After 30 minutes of non-use before a measurement Dimensions/Weight: 142.5 x 102.5 x 50.5 mm/380 g Expired standard solutions: 08/2022

Options :

Photomètre ammoniaque HANNA HI97715C avec malette, jusqu'à 10,0 mg/L Matériel neuf dans son emballage d'origine HI97715C est livré en mallette de transport avec 2 cuvettes de mesure, bouchons plastique et capuchons, tissus de nettoyage, ciseaux et piles. Gamme : 0,10 à 10,00 mg/L (NH₃-N) Résolution : 0,01 mg/L Exactitude à 25 °C : ±0,05 mg/L ±5% de la lecture Méthode : Adaptation de la méthode «ASTM Manual of Water et Environmental Technology, D1426-92», Méthode Nessler Source lumineuse : DEL avec filtre à bande passante étroite 420 nm Détecteur de lumière : Photocellule au silicium Piles/Durée de vie : 3 x 1,5 V AA / > 800 mesures sans rétroéclairage Mémorisation à la demande : Jusqu'à 50 mesures pour un rappel à l'écran Auto-extinction : Après 15 minutes de non-utilisation / Après 30 min de non-utilisation avant une mesure Dimensions /Poids : 142,5 x 102,5 x 50,5 mm/380 g solutions étalons expirées : 08/2022

The Offer Details are provided by the seller and automatically translated.

Description

HI97715C – Portable Photometer for Ammonia: Field Performance and Analytical Reliability

The HI97715C photometer from Hanna Instruments is specially designed to meet the requirements of ammonia nitrogen analysis in natural, industrial or waste water. Ammonia, in dissolved form in water, is a critical indicator of pollution and can be extremely toxic to aquatic environments in excessive concentrations. The HI97715C provides accurate and reproducible measurements of this indicator using proven optical technology, while ensuring ease of use in the field.

Based on the Nessler method, in accordance with ASTM D1426-92, the HI97715C uses a 420 nm LED light source and a silicon photometric cell to ensure remarkable accuracy. The instrument has a resolution of 0.01 mg/L and a measurement range from 0.10 to 10.00 mg/L of NH₃-N, with an accuracy of ±0.05 mg/L or ±5% of the reading at 25°C. This performance makes it ideal for environmental professionals or field operators who need a compact, reliable and efficient device.

The device comes with a sturdy carrying case containing all the accessories needed to get started right away: cuvettes, CAL CHECK certified calibration solutions, cleaning cloths, scissors and batteries. Thanks to the CAL CHECK function, the user can check and adjust the accuracy of the instrument at any time using certified standards. The GLP function allows calibration data to be recorded to ensure complete traceability in accordance with good laboratory practice.

The HI97715C is equipped with a multi-level illuminated display with an intuitive virtual keypad interface, making it easy to use even in low light conditions. Its IP67-rated housing ensures optimal protection against water and dust, and its floating design prevents loss if accidentally dropped in a wet environment. With over 800 measurements on battery power without backlighting, this device is a reliable long-term ally.

All these features make the HI97715C the ideal choice for professionals looking for a robust, accurate and easy-to-use portable photometer for ammonia analysis in aqueous media.

Features

  • Accurate measurement of ammonia (NH₃-N) using a recognised method
  • CAL CHECK function with standard solutions to verify accuracy
  • GLP function for saving calibration data
  • Intuitive interface with virtual keys and backlit display
  • Compact, portable device, resistant to field conditions
  • Internal memory for 50 measurements for effective monitoring
  • Compliance with USEPA requirements for environmental analysis
  • Very low cost per test, ideal for regular campaigns

Technical Details

  • Measurement range: 0.10 to 10.00 mg/L (NH₃-N)
  • Resolution: 0.01 mg/L
  • Accuracy at 25 °C: ±0.05 mg/L or ±5% of reading
  • Method: Adapted from ASTM D1426-92 (Nessler method)
  • Light source: Narrow bandpass LED (420 nm)
  • Detector: Silicon photocell
  • Memory: Up to 50 measurements
  • Auto-off: After 15 or 30 minutes of inactivity
  • Power supply: 3 AA batteries (1.5 V), battery life >800 measurements
  • Dimensions: 142.5 x 102.5 x 50.5 mm
  • Weight: 380 g
  • Protection rating: IP67 (waterproof and floatable)

Compatible Accessories

  • HI93715-01: Reagents for 100 medium range ammonia tests
  • HI93703-50: Cleaning solution for cuvettes
  • HI731318: Cleaning cloths for cuvettes
  • HI731331: Glass measuring cells
  • HI731336N: Replacement caps for cuvettes

Logistics

Remma and its partners provide you with serviced and configured equipment tailored to your needs. Receive your product at your facility with standard or express delivery, and an installation option, all through a single point of contact.

Warranty

Our 12/24-month warranty ensures the safety and reliability of your medical equipment throughout its lifespan.

Flexible Financing

Settle your medical equipment in up to 36 installments with our financing service or pay after delivery with Remma Facility.