Neonatal intensive care ventilator BABYLOG 8000 PLUS - Good

Brand: Dräger


Dräger Medical's Babylog 8000 Plus neonatal intensive care ventilator revolutionizes neonatal ventilation with Volume Guarantee and High Frequency Ventilation modes. Its seamless integration with the BabyFlow nasal CPAP system ensures non-invasive support, while Dräger's accessories like the VarioLux examination light optimize care. Engineered for precision and simplicity, these innovations enhance neonatal care, offering peace of mind to healthcare providers and promoting the best outcomes for tiny patients.

Offer Details

Accessories :

sold with trolley

Description

Enhancing Neonatal Care: Dräger Babylog 8000 Plus and Compatible Accessories

Dräger Medical's Babylog 8000 plus has been a trusted choice in neonatal ventilation, drawing from a century of expertise in breathing technology. This ventilator is meticulously designed to meet the rigorous standards of care required for neonatal patients. Its features are tailored to ensure precise synchronization and continuous adaptation, providing optimal ventilator support while allowing for spontaneous breathing. This harmony between the ventilator and the baby helps facilitate the weaning process and safeguards against potential complications such as volutrauma or atelectasis.

One of the standout features of the Babylog 8000 plus is its Volume Guarantee (VG) function, which combines the benefits of pressure and volume controlled ventilation. With VG, a preset tidal volume is maintained consistently, regardless of variations in spontaneous breathing strength or changes in lung conditions. This ensures sufficient ventilation while minimizing the risk of volutrauma, offering peace of mind to healthcare providers and caregivers alike.

The ventilator also offers High Frequency Ventilation (HFV) capability, easily accessible with the touch of a button. This mode can be used in conjunction with Continuous Positive Airway Pressure (CPAP) or Intermittent Mandatory Ventilation (IMV) modes, allowing for precise adjustment of therapy to suit individual patient needs. Notably, while HFV is a versatile option globally, it is not available in the USA.

Pressure Support Ventilation (PSV) is another key feature, recognized as a standard in neonatal care. With automatic leak compensation and synchronized inspiration and expiration, PSV empowers infants with more control over their breathing patterns. Continuous, automatic leak compensation ensures optimal inspiration times, further enhancing the effectiveness of ventilation therapy.

The Babylog 8000 plus not only excels in invasive ventilation but also offers the benefits of non-invasive support with the integration of the BabyFlow nasal CPAP system. Specifically engineered for the smallest patients, this nasal CPAP system is designed to be user-friendly and highly effective. Its unique mask design overcomes historical challenges, ensuring stable and gentle delivery of CPAP therapy without causing trauma to the delicate nasal passages of neonates.

Compact and seamlessly blending into the neonatal intensive care unit (NICU) environment, the BabyFlow nasal CPAP system is both unobtrusive and intuitive to use. With just six clearly labeled control knobs, operators can quickly familiarize themselves with the device and start delivering therapy without delay. This simplicity in design and operation allows healthcare professionals to focus their attention on providing the best possible care to their tiny patients, rather than struggling with complicated equipment.

Moreover, the BabyFlow nasal CPAP system is equipped with intelligent alarm features that enhance workflow efficiency. By promptly alerting caregivers to any deviations from the desired parameters, these alarms ensure that attention is directed where it's most needed – on the baby. This streamlined approach to monitoring and alarm management not only simplifies the caregiving process but also helps to maintain a high standard of patient safety and comfort in the NICU.

In addition to its core functionalities, the Babylog 8000 plus is complemented by compatible accessories that further enhance its capabilities in neonatal intensive care settings. One such accessory is the Dräger VarioLux examination light, which is purposefully designed to meet the unique needs of neonatal care units. This versatile examination light delivers cool, highly efficient illumination with variable intensity, ensuring optimal visibility during delicate procedures. Its single-handed operation capability allows healthcare professionals to maintain focus on their tasks while easily adjusting the light's color settings and brightness levels to suit specific requirements.

Furthermore, Dräger offers a comprehensive range of neonatal care accessories tailored for use with the Babylog 8000 plus and other ventilation and thermotherapy equipment. These accessories are meticulously crafted to provide gentle and effective support to newborns, minimizing stress and promoting their development in the crucial early stages of life. Whether it's specialized ventilation circuits, patient interfaces, or monitoring tools, Dräger accessories are designed to optimize the functionality and performance of neonatal care equipment, ensuring the highest standards of care for the smallest of patients.

With Dräger's commitment to innovation and quality, healthcare providers can trust that these accessories are designed and manufactured to the same exacting standards as the Babylog 8000 plus itself. By integrating these accessories into their neonatal care protocols, healthcare teams can deliver comprehensive and tailored support to newborns, addressing their unique needs with precision and care.

Features

    • Controlled and Assisted Ventilation

    • Various ventilation modes (controlled ventilation, assisted ventilation, high-frequency ventilation)

    • User-friendly interface for easy setup

    • Precise monitoring of respiratory volumes and pressures

    • Oxygen saturation monitoring

    • Detection of significant changes in respiratory parameters

Technical Details

    • Controls
      • Control principle Continuous flow, pressure-limited, time-cycled
      • Conventional ventilation IMV/IPPV, CPAP
      • Triggered ventilation IMV, SIPPV, PSV1, Leak adapted
      • Trigger Flow/volume trigger, Leak adapted
      • Trigger delay Approx. 30 ms
      • High Frequency Ventilation1 3 CPAP+HFV, IMV+HFV
      • Frequency 5 to 20 Hz
      • Volume Gurantee Ventilation1 SIMV+VG, SIPPV+VG, PSV+VG
      • Oxygen mixer loss (bleed flow) 0 (zero) L/min

    • Monitoring
      • Flow Monitoring At the Y-piece, integrated
      • Volume Monitoring At the Y-piece, integrated
      • Lung function monitoring Compliance, resistance C20/C, time constant, r
      • FiO2 Monitoring Integrated
      • Real-time curves Flow and pressure, integrated
      • Inspiratory Oxygen concentration 21–100 vol.% oxygen
      • Peak Pressure To 99 mbar
      • Mean Airway Pressure To 99 mbar
      • Graphic trends 6 parameters, integrated
      • Logbook Record of last 100 alarms

Attention: For more information, please refer to the PDF file.

Compatible Accessories

    • Dräger VarioLux

Explore

Servicing and Logistics

Remma and its partners provide you with serviced and configured equipment tailored to your needs. Receive your product at your facility with standard or express delivery, and an installation option, all through a single point of contact.

Warranty

Our 12/24-month warranty ensures the safety and reliability of your medical equipment throughout its lifespan.

Flexible Financing

Settle your medical equipment in up to 36 installments with our financing service or pay after delivery with Remma Facility.