• Medical Imaging Medical Imaging
  • Ophtalmology Ophtalmology
  • Operating Room Operating Room
  • Anesthesia Anesthesia
  • Laboratory Laboratory
  • Dental Equipment Dental Equipment
  • Gastroenterology Gastroenterology
  • Obstetrics and Gynecology Obstetrics and Gynecology
  • Cardiology Cardiology
  • Emergency Medicine Emergency Medicine
  • Comfort and Well-being Comfort and Well-being
  • Dermatology Dermatology
  • Healthcare Furniture Healthcare Furniture
  • Urology and Nephrology Urology and Nephrology
  • ENT ENT
  • Orthopaedics Orthopaedics
  • Physical Therapy and Rehabilitation Physical Therapy and Rehabilitation
  • Sterilization Sterilization
  • Intensive Care Intensive Care
  • Surgical Instruments Surgical Instruments

OCT DRI Triton

Brand: Topcon
Categories: Ophtalmology

Be notified by email when the product is available
Subscribe to our partner program and become a Remma seller.


The Topcon DRI OCT Triton integrates Swept Source OCT technology with multimodal fundus imaging, offering unparalleled diagnostic capability. With features like true color fundus imaging and Dynamic Focus, it provides clear insights into ocular structures. The device's efficiency-enhancing functions streamline workflow, allowing clinicians to focus on patient care. Triton enables comprehensive evaluations with stereo photography and panoramic wide field imaging, while its intuitive follow-up function ensures longitudinal assessment accuracy.

Description

Topcon DRI Triton OCT: Advanced Swept Source Technology for Comprehensive Eye Imaging

The DRI OCT Triton from Topcon represents a breakthrough in ocular imaging, combining the world’s first Swept Source OCT technology with multimodal fundus imaging. This state-of-the-art device is designed to provide eye care professionals with unparalleled image quality, diagnostic capability, and practice efficiency.

The Triton’s Swept Source OCT technology, operating at a 100 kHz scanning speed and utilizing a 1,050nm wavelength, ensures exceptionally clear and detailed images. This advanced imaging capability penetrates even the deepest layers of the eye with minimal acquisition time, allowing for comprehensive visualization of the retina, vitreous, choroid, and sclera. Such detailed imaging is crucial for accurately diagnosing and monitoring various ocular conditions.

The ability to see deeper into the eye with the Triton opens new possibilities for understanding a wide range of ocular pathologies. The device is equipped with OCT angiography, fundus autofluorescence, and en face OCT, providing a multimodal imaging approach. These features empower clinicians to perform thorough assessments and create detailed treatment plans, ultimately aiming to preserve and improve patients' eye health.

The Triton is designed with the efficiency of modern medical practices in mind. Its automated functions, including single scan captures and the SMARTTrack system, streamline the workflow by simplifying data capture, analysis, and follow-up procedures. These advancements not only enhance the accuracy and reliability of diagnostic processes but also allow practitioners to spend more time focusing on patient care.

In addition to its Swept Source OCT technology and multimodal imaging features, the DRI OCT Triton offers true color fundus images, providing eye care professionals with comprehensive diagnostic insights. These non-mydriatic fundus images offer a true representation of ocular structures, enhancing diagnostic accuracy.

The Triton's Dynamic Focus feature revolutionizes imaging by enabling the acquisition of images with near uniform focus and image quality throughout the entire depth of the image. This technology is particularly beneficial for enhancing image clarity in regions with typically weaker signals, such as the vitreous, ensuring accurate interpretation of ocular structures.

Understanding choroidal structural changes is essential for evaluating various ocular diseases and their management. Triton facilitates clear visualization of the choroid and generates choroidal thickness maps. These maps provide clinicians with valuable information to assess choroidal structure, aiding in the diagnosis and monitoring of conditions affecting this important ocular layer.

The DRI OCT Triton introduces stereo photography mode, enabling three-dimensional visualization of color fundus images. By acquiring images in stereo photography mode, clinicians can achieve depth perception, enhancing their ability to assess ocular structures accurately. Triton's on-screen acquisition guidance simplifies the operation with auto alignment for capturing stereo pairs, ensuring quick and precise image acquisition.

In addition to macular and disc imaging, the Triton offers wide coverage of the retina through panoramic wide field photography. This feature allows clinicians to create panoramic graphics from multiple fundus or OCT Angiography images, providing a comprehensive view of the retinal landscape. With panoramic imaging capabilities, Triton facilitates thorough evaluations of retinal pathology and disease progression.

The Triton streamlines follow-up procedures with its intuitive follow-up function. This feature enables clinicians to retrieve and re-analyze the same location at follow-up appointments, facilitating comparison of past and current images. With a simple selection of past data, Triton automatically captures the same area, ensuring consistency and accuracy in longitudinal assessments. This functionality enhances clinical decision-making by providing insights into disease progression and treatment efficacy over time.

In summary, the DRI OCT Triton enhances diagnostic capabilities and practice efficiency with stereo photography for three-dimensional visualization, panoramic wide field photography for comprehensive retinal coverage, and effortless follow-up functionality for longitudinal assessments. By combining advanced imaging modalities with user-friendly features, Triton empowers clinicians to deliver exceptional patient care and monitor ocular health with confidence.

Features

    • Swept Source OCT technology

    • Multimodal fundus imaging

    • Automated functions

    • True color fundus images

    • OCT angiography

    • Fundus autofluorescence

    • En face OCT

    • Dynamic Focus feature

    • Choroidal thickness maps

    • Stereo photography mode

    • Panoramic wide field photography

    • Effortless follow-up functionality

Technical Details

    • Dimensions: 320-359 mm (D) x 523-554 mm (W) x 560-590 mm (H)
    • Weight: 21.8 kg (DRI OCT Triton)

Please note: For more information, please refer to the PDF file.

Compatible Accessories

Without accessories.

Servicing and Logistics

Remma and its partners provide you with serviced and configured equipment tailored to your needs. Receive your product at your facility with standard or express delivery, and an installation option, all through a single point of contact.

Warranty

Our 12/24-month warranty ensures the safety and reliability of your medical equipment throughout its lifespan.

Flexible Financing

Settle your medical equipment in up to 36 installments with our financing service or pay after delivery with Remma Facility.