• Medical Diagnostic Equipment
  • Surgical and Therapeutic Equipment
  • Medical Furniture
  • Laboratory Equipment
  • Cleaning and Sterilization

Clarus 680 Chromatograph - Good Condition

The Clarus 680 GC from PerkinElmer is a high-performance gas chromatograph designed for high-throughput laboratories requiring fast analytical cycle times. With a temperature control range from 5°C above ambient temperature to 450°C, it enables the separation and analysis of a wide range of compounds. Featuring an electronic pressure control (EPC) system and a colour touchscreen interface, the Clarus 680 GC delivers sample injection accuracy of less than 0.5% RSD, ensuring reliability and accuracy for demanding analytical tasks. Its patented oven design enables fast heating and cooling times, maximising sample throughput.



Description

Clarus 680 Gas Chromatograph: Performance and Precision for Modern Laboratories

The Clarus 680 GC from PerkinElmer is a state-of-the-art gas chromatograph designed specifically to meet the demands of modern high-throughput laboratories. This system is ideal for environments where speed and accuracy are critical. With its innovative technology and robust design, the Clarus 680 GC delivers exceptional performance for a wide range of analytical applications.

The Clarus 680 GC is equipped with a state-of-the-art electronic pressure control (EPC) system, ensuring unmatched accuracy and repeatability in gas flow control. This system provides accuracy of ±0.001 psi, which is essential for reliable and repeatable analytical results. In addition, the Clarus 680 GC supports dual-channel configurations, enabling simultaneous analysis with two different detectors, such as FID, TCD, ECD or MS, offering great flexibility in applications.

One of the major advantages of the Clarus 680 GC is its patented high-performance oven, which enables extremely fast heating and cooling times . The oven can reach temperatures ranging from 5°C above ambient temperature to 450°C, with a cooling time of less than 2 minutes from 450°C to 50°C. This feature significantly reduces analysis times and increases sample throughput, which is particularly advantageous for laboratories handling large sample volumes.

The Clarus 680 GC also features an intuitive colour touchscreen interface, making it easy to configure methods and operate the instrument. This user-friendly interface allows users of all skill levels to take full advantage of the instrument's capabilities. In addition, the Clarus 680 GC is compatible with PerkinElmer's TotalChrom software, which offers robust data management and reporting capabilities, simplifying analysis and interpretation of results.

The Clarus 680 GC's sample injection accuracy is less than 0.5% RSD, ensuring high reliability and accuracy for the most demanding analytical tasks. This accuracy is essential for obtaining consistent and reproducible results, which is crucial for laboratory decision-making.

The Clarus 680 GC from PerkinElmer is a high-performance gas chromatograph designed to meet the needs of modern high-throughput laboratories. With its technology, robust design and user-friendly interface, it offers exceptional performance for a wide range of analytical applications. Whether for solvent analysis, pesticide determination in food or other complex applications, the Clarus 680 GC is the instrument of choice for demanding laboratories.

Features

  • Patented furnace design for fast heating and cooling times, maximising sample throughput.
  • Electronic pressure control (EPC) system for unmatched accuracy and reproducibility.
  • Intuitive colour touchscreen interface for easy method setup and simplified operation.
  • Compatibility with TotalChrom software for robust data management and reporting.
  • Sample injection accuracy of less than 0.5% RSD, ensuring reliable and reproducible analytical results.
  • Supports dual-channel configurations for simultaneous analysis with different detectors.
  • Double-walled furnace design with concentric air exhaust for better separation at temperatures close to ambient.
  • Programmable Split-Splitless (PSS) and Programmable On-Column (POC) injectors for large-volume injections and cold injections on column.
  • Swafer™ micro-flow technology to simplify complex tasks and improve productivity.

Technical Details

  • Temperature control range: 5°C above ambient temperature to 450°C
  • Electronic pressure control (EPC) system accuracy: ±0.001 psi
  • Sample injection accuracy: <0.5% RSD
  • Oven cooling time: less than 2 minutes from 450°C to 50°C
  • Interface: large colour touchscreen
  • Software compatibility: PerkinElmer TotalChrom
  • Dimensions (with automatic sampler): 670 × 820 × 830 mm
  • Weight (with automatic sampler): 69 kg

Compatible Accessories

  • Various gas sampling valves, including 4-, 6-, 8-, and 10-port valves.
  • A wide range of standard valve systems and analysers.
  • Various detectors optimised for sensitivity and selectivity, such as the flame ionisation detector (FID), thermal conductivity detector (TCD), electron capture detector (ECD), and environment-specific detectors.

Logistics

Remma and its partners provide you with serviced and configured equipment tailored to your needs. Receive your product at your facility with standard or express delivery, and an installation option, all through a single point of contact.

Warranty

Our 12/24-month warranty ensures the safety and reliability of your medical equipment throughout its lifespan.

Flexible Financing

Settle your medical equipment in up to 36 installments with our financing service or pay after delivery with Remma Facility.