• Medical Imaging Medical Imaging
  • Ophtalmology Ophtalmology
  • Operating Room Operating Room
  • Anesthesia Anesthesia
  • Laboratory Laboratory
  • Dental Equipment Dental Equipment
  • Gastroenterology Gastroenterology
  • Obstetrics and Gynecology Obstetrics and Gynecology
  • Cardiology Cardiology
  • Emergency Medicine Emergency Medicine
  • Comfort and Well-being Comfort and Well-being
  • Dermatology Dermatology
  • Healthcare Furniture Healthcare Furniture
  • Urology and Nephrology Urology and Nephrology
  • ENT ENT
  • Orthopaedics Orthopaedics
  • Physical Therapy and Rehabilitation Physical Therapy and Rehabilitation
  • Sterilization Sterilization
  • Intensive Care Intensive Care
  • Surgical Instruments Surgical Instruments

Slit lamp BQ 900 - Excellent 2004

Categories: Ophtalmology


The BQ 900 slit lamp offers precise eye examinations with versatility. Featuring a meticulously crafted optical system, it delivers unparalleled visual clarity for accurate diagnostics and imaging outcomes. Renowned for its Goldmann applanation tonometer, it ensures reliable tonometry measurements with minimal maintenance. Ergonomic design and unique features like the stereo variator enhance user comfort and facilitate detailed fundus examinations. Compatible with EyeSuite software, it streamlines patient management and enables remote access to captured images for collaborative care. With extensive compatibility with EMR systems, it ensures efficient data integration and comprehensive patient records.

Offer Details

Dernière révision 2023

Vendu avec diviseur d'angles

Description

BQ 900 Slit Lamp: Detailed Eye Examination with Precision and Versatility

The BQ 900 slit lamp stands as a testament to the crucial role that the optical system plays in determining the efficacy of any application it is utilized for. At the core of the BQ 900 lies an intricately designed optical system, meticulously crafted to meet the highest quality standards. This results in an unparalleled visual experience, providing clinicians with a clear and precise view necessary for accurate diagnostics, safe patient treatment, and remarkable imaging outcomes.

In addition to its exceptional functionality, the BQ 900 slit lamp is designed with ergonomic considerations to promote comfortable and fatigue-free working conditions for clinicians. The inclined eyepiece adaptor tilts the view into the microscope at a 20-degree angle to the horizontal, allowing examiners to use the slit lamp in a more relaxed position, reducing strain during prolonged examinations.

Furthermore, the BQ 900 incorporates unique features to enhance the view of the fundus, such as the stereo variator. This innovative component reduces the angle of stereoscopic observation from 13° to 4.5°, facilitating detailed examination of the fundus, peripheral retina, and vitreous. Even under challenging conditions like high myopia and small pupils, the reduced angle expands the stereoscopic field of view, ensuring depth information is preserved for accurate diagnosis and treatment planning.

Analog co-observing is a valuable feature of Haag-Streit's slit lamps, allowing professional colleagues, students, or technicians to actively participate in examinations. The second observer tubes are specifically designed to accommodate this function, with two versions available: a short version for co-observing in a sitting position and a long version for co-observing in an upright position. This feature promotes collaboration and knowledge sharing during clinical assessments, enhancing the educational and diagnostic capabilities of the slit lamp system.

Another noteworthy enhancement offered by the BQ 900 slit lamp is fluorescence enhancement, facilitated by a yellow barrier filter. This filter adds contrast to fluorescein images, aiding clinicians in detecting subtle changes or abnormalities in ocular tissues. Easily mountable on the slit lamp, the filter can be inserted or removed as needed, providing flexibility and convenience during examinations.

Moreover, the EyeSuite software is seamlessly integrated with the BQ 900 slit lamp, optimizing patient flow in busy clinical settings. Compatible with Haag-Streit imaging solutions, this software enables network connectivity between the slit lamp and other Haag-Streit devices, as well as with the practice network. Notably, EyeSuite eliminates the need for proprietary third-party software for connectivity, simplifying the setup process.

By connecting the slit lamp to an EyeSuite server, clinicians gain remote access to all captured images from any viewing station linked to the same database. This remote accessibility enhances collaboration among healthcare professionals and facilitates comprehensive patient care, regardless of location.

Furthermore, the EyeSuite software offers extensive compatibility with electronic medical record (EMR) systems through standardized interfaces like GDT or DICOM. Patient orders received from the EMR system can be seamlessly integrated with the slit lamp workflow, ensuring efficient data management and streamlined documentation. Additionally, captured images are automatically transferred back to the EMR system, ensuring comprehensive patient records and facilitating continuity of care.

Features

    • Elaborated optical system for precise examination

    • Goldmann applanation tonometry for accurate intraocular pressure measurement

    • Ergonomic design with inclined eyepiece adaptor for fatigue-free working

    • Stereo variator for enhanced fundus view

    • Analog co-observing for collaborative examinations

    • Fluorescence enhancement with yellow barrier filter

    • Integration with EyeSuite software for streamlined patient management

Technical Details

    • Illumination
      • Light-source: LED for examination (slit and background illumination)
      • Slit width: 0 – 14mm continuous
      • Slit length: 1 – 14mm continuous and fixed apertures
      • Illumination field diameter: ø 8/5/3/2/1/0.2mm, test mark with fixation star
      • Slit image rotatability: ± 90°
      • Swiveling of the slit illumination to the microscope axis: Horizontal ± 90°, vertical 0 – 20°
      • Filters: Blue, red-free (green) and grey (10%)

    • Measures (W×L×H) 332mm×305mm×700mm
    • Weight: 12.7 kg

Attention: For more information, please refer to the PDF file.

Compatible Accessories

Attention: For information on compatible accessories, please refer to the PDF.

Explore

Servicing and Logistics

Remma and its partners provide you with serviced and configured equipment tailored to your needs. Receive your product at your facility with standard or express delivery, and an installation option, all through a single point of contact.

Warranty

Our 12/24-month warranty ensures the safety and reliability of your medical equipment throughout its lifespan.

Flexible Financing

Settle your medical equipment in up to 36 installments with our financing service or pay after delivery with Remma Facility.