The Memmert SN55 hot air steriliser is designed to ensure reliable sterilisation of laboratory instruments at temperatures up to 250 °C. Thanks to its precise digital control technology, Setpoint Wait function and stainless steel design, it offers optimum safety and ease of maintenance. Compact, robust and compliant with medical standards, it fits perfectly into demanding laboratory environments, ensuring consistent and efficient sterilisation without compromising on quality.



Offer Details

Options :

Memmert Heissluftsterilisator SN55, 53l, 20-250°C

The Offer Details are provided by the seller and automatically translated.

Description

Memmert SN55 steriliser: reliability and performance for laboratory sterilisation

The Memmert SN55 hot air steriliser is a particularly reliable and high-performance thermal sterilisation solution for laboratories, medical centres and research facilities. Designed to ensure the complete destruction of microorganisms, it replaces disinfection with true sterilisation, thus complying with all regulatory requirements for medical devices. With its 53-litre chamber and load capacity of up to 80 kg, it effectively meets the needs of small and medium-sized facilities. The device operates on the principle of natural convection with a controlled supply of preheated fresh air, ensuring even heat distribution and consistent results regardless of the position of the instruments inside.

Precise temperature control for controlled sterilisation

The SN55 is equipped with a digital PID control system based on a multifunction microprocessor with a high-definition TFT colour display. This system offers optimum precision, allowing temperature settings from +20 to +250°C, with an accuracy of 0.1°C below 99.9°C and 0.5°C above. One of the key features of this device is the Setpoint Wait function, which ensures that the sterilisation process only starts when the programmed temperature is reached. This mechanism can be applied with Pt100 temperature sensors placed freely in the chamber to validate that all measuring points have reached the target temperature before the sterilisation phase begins. This feature is essential for ensuring maximum cycle efficiency and flawless safety.

Robust design and user-friendly interface for simplified use

The interior structure of the SN55 steriliser is made entirely of stainless steel, with pressed ribs and protected heating on all four sides, ensuring both excellent thermal conductivity and remarkable ease of cleaning. The stainless steel door is equipped with a two-point compression lock, guaranteeing a perfect seal during sterilisation cycles. The ControlCOCKPIT SingleDISPLAY control panel makes programming intuitive, with detailed configuration options including temperature setting in Celsius or Fahrenheit, air valve control, programme time and time zones. In the event of a power failure, the programme data is automatically saved, enhancing the reliability of the appliance.

The integration of AtmoCONTROL software via USB or Ethernet interface enables advanced sterilisation data management and accurate cycle history tracking for full traceability.

Features

  • Natural convection technology with preheated fresh air supply
  • Heating distributed across all four sides of the chamber
  • Digital control interface with high-resolution TFT colour display
  • Setpoint Wait function to start the cycle only at the target temperature
  • Digital programmer with countdown timer up to 99 days
  • Calibration function at three freely selectable temperatures
  • Electronically adjustable air vent
  • Two-point compression door lock
  • Calibration certificate at +160 °C included
  • Self-diagnostic system for fault analysis
  • Safety system with dual overheating protection (electronic and mechanical)
  • Programme backup in case of power failure
  • AtmoCONTROL software can be integrated via USB or Ethernet


Technical Details

  • Temperature range: +20 °C to +250 °C
  • Display accuracy: 0.1 °C (up to 99.9 °C), 0.5 °C (above)
  • Sensor: 1 Pt100 class A sensor in a 4-wire circuit
  • Interior volume: 53 litres
  • Internal dimensions (W x H x D): 400 x 400 x 330 mm
  • External dimensions (W x H x D): 585 x 784 x 514 mm (+56 mm handle)
  • Maximum load: 80 kg
  • Maximum load per level: 20 kg
  • Maximum number of shelves: 4
  • Power supply: 230 V / 50–60 Hz (2000 W) or 115 V / 50–60 Hz (1700 W)
  • Net weight: 57 kg
  • Permissible ambient temperature: +5 °C to +40 °C
  • Maximum installation altitude: 2000 m
  • Overvoltage category: II
  • Pollution degree: 2


Compatible Accessories

  • Additional stainless steel grids
  • USB stick containing the AtmoCONTROL software
  • Freely positionable Pt100 temperature sensors
  • External calibration kit
  • Instrument holders
  • Wall mounting or trolley mounting system
  • Perforated stainless steel tray
  • Dust cover