• Medical Diagnostic Equipment
  • Surgical and Therapeutic Equipment
  • Medical Furniture
  • Laboratory Equipment
  • Cleaning and Sterilization
  • Spare Parts

SN55plus Hot Air Steriliser

The Memmert SN55plus hot air steriliser is designed to guarantee reliable sterilisation in accordance with current standards for medical devices. Thanks to its TwinDISPLAY digital control technology and two high-precision Pt100 sensors, it ensures precise temperature control from +20 to +250 °C. Its SetpointWAIT function only starts the cycle when the programmed temperature is reached, ensuring optimum safety. With a volume of 53 litres, a stainless steel construction and natural convection ventilation, it meets the strict requirements of laboratories and medical environments.



Description

SN55plus Memmert – High-precision hot air steriliser for laboratories and medical use

The Memmert SN55plus hot air steriliser is specially designed to ensure consistent and safe sterilisation of instruments in laboratories and medical environments. In accordance with the standards and regulations applicable to medical devices, it uses a high-performance natural convection heating system, guaranteeing optimum heat distribution throughout the chamber. Its 53-litre usable volume allows several loads to be processed simultaneously, while maintaining consistent efficiency thanks to precise temperature control. Its robust design, combined with an all-stainless steel construction, ensures not only exceptional durability but also simplified maintenance, meeting the daily needs of the most demanding environments.

Precise control technology and integrated safety

The Memmert SN55plus is equipped with two class A Pt100 probes, mounted in a 4-wire circuit for reliable and redundant measurement. This configuration allows constant temperature monitoring and ensures that sterilisation only starts once the target temperature has been reached, thanks to the SetpointWAIT function. The latter measures the temperature at different points to ensure that each zone of the chamber complies with the defined parameters. The HeatBALANCE function allows the heat distribution between the upper and lower circuits to be adjusted, optimising performance according to the type of load. The AutoSAFETY system automatically monitors any critical variations, triggering a visual and audible alarm and stopping the heating in the event of overheating. An internal self-diagnostic function quickly detects anomalies, helping to maintain safe and consistent operation.

Ease of use and high-performance connectivity

Designed to make the user's work easier, the SN55plus features a TwinDISPLAY control panel with two high-definition TFT colour screens, allowing intuitive setting of temperature, time and ventilation settings. The digital timer offers a setting range from 1 minute to 99 days, allowing sterilisation cycles to be adapted to each application. The device is compatible with AtmoCONTROL software, allowing programmes to be created, managed and transferred via USB or Ethernet. Even in the event of a power failure, programme data is retained, ensuring continuity and traceability of operations. The interior chamber can accommodate up to four electropolished stainless steel shelves, supporting a total load of 80 kg. The insulated door, equipped with a two-point lock, ensures optimal thermal sealing.

All these features make the Memmert SN55plus an essential tool for any organisation requiring precise, reliable and repeatable sterilisation.

Features

  • TwinDISPLAY technology with dual high-definition TFT colour screens
  • Multifunction digital PID controller with adjustable parameters
  • SetpointWAIT function for delayed start of sterilisation time
  • HeatBALANCE function for top/bottom thermal balancing
  • AutoSAFETY automatic over/under-temperature monitoring system
  • Integrated visual and audible alarm
  • Documentation retained in the event of a power failure
  • Insulated stainless steel door with two-point locking
  • Easy-to-clean, reinforced and protected interior chamber
  • Programming and monitoring via AtmoCONTROL software and Ethernet/USB interface

Technical Details

  • Temperature setting range: +20 to +250 °C
  • Display accuracy: 0.1 °C up to 99.9 °C / 0.5 °C from 100 °C
  • Deviation from ambient temperature: minimum +5 °C
  • Sensors: 2 Pt100 class A probes in a 4-wire circuit
  • Useful volume: 53 litres
  • Internal dimensions (W x H x D): 400 x 400 x 330 mm
  • External dimensions (W x H x D): 585 x 784 x 514 mm (+ 56 mm handle)
  • Maximum load per level: 20 kg (80 kg total)
  • Ventilation: natural convection with electronically adjustable air flap
  • Power supply: 230 V, 50/60 Hz, 2000 W or 115 V, 50/60 Hz, 1700 W
  • Net weight: 57 kg

Compatible Accessories

  • Additional electropolished stainless steel grilles
  • Removable supports and trays
  • Freely positionable external Pt100 probes
  • Additional shelf kit for heavy loads
  • Set of replacement air filters
  • AtmoCONTROL USB key for programme management

Logistics

Remma and its partners provide you with serviced and configured equipment tailored to your needs. Receive your product at your facility with standard or express delivery, and an installation option, all through a single point of contact.

Warranty

Our 12/24-month warranty ensures the safety and reliability of your medical equipment throughout its lifespan.

Flexible Financing