Microliter Syringe 80500 - Perfect Condition

The Hamilton 80500 microlitre syringe is a precision instrument designed for analytical applications requiring extremely low volumes. With a capacity of 50 µL, it features a 22s gauge cemented needle with a curved tip (Style 2) for fine, targeted injection. Its high-quality borosilicate glass body and stainless steel fluid path guarantee optimal chemical compatibility. Non-autoclavable but gas-sterilisable, it is ideal for injections into split/splitless systems in chromatography. It is suitable for environments requiring reliability, precision and durability with every use.



Description

Hamilton 80500 Microlitre Syringe: A precision solution for demanding analytical handling

The Hamilton 80500 microlitre syringe is specifically designed to meet the demands of modern analytical laboratories, where precision and reliability of injected volumes are paramount. With a nominal capacity of 50 µL, this syringe is part of Hamilton's 700 series, renowned for its exceptional accuracy in microvolume dispensing.

This syringe is constructed from high-quality materials that ensure long-lasting durability and stable performance over time. Its borosilicate glass barrel is particularly resistant to aggressive chemicals while allowing for clear visual reading of the volume. The cemented needle is made of stainless steel (SST), a material known for its strength, corrosion resistance and compatibility with a wide variety of solvents and samples.

The 80500 model is equipped with a 22s needle with a style 2 tip, i.e. curved and bevelled. This configuration optimises injection into septa by minimising seal wear and facilitating penetration into heated injection chambers, which are typical of gas chromatography systems. Thanks to its compact and precise design, this syringe is particularly suitable for injections into split/splitless chambers, in which the sample is instantly vaporised.

In terms of performance, the Hamilton 80500 syringe can withstand pressures of up to 2000 psig (137.9 bar), making it a robust choice for high-stress environments. It can operate in a temperature range of 10 to 50 °C, meeting the majority of laboratory experimental conditions.

Another key feature of this model is its standard dead volume of just 1.13 µL, which reduces sample loss and improves overall analysis accuracy. This is particularly beneficial in protocols requiring precise dosages of expensive or low-concentration substances.

The 80500 syringe is not autoclavable, which limits its use in environments requiring high-temperature sterilisation. However, it is gas-sterilisable, allowing safe reuse in most analytical applications. Its compatibility with automated and manual analytical systems makes it a versatile choice for research, quality control, analytical chemistry, and bioanalysis laboratories.

The Hamilton 80500 syringe embodies precision, reliability and robustness, while integrating seamlessly with the requirements of modern analytical techniques. It is the solution of choice for professionals seeking to combine methodological rigour with technical performance.


Features

  • Borosilicate glass and stainless steel construction for excellent chemical resistance
  • Pre-assembled cemented needle for immediate and safe use
  • Precise calibration for accurate micro-volume delivery
  • Style 2 needle optimises injection through septa
  • Ideal for split/splitless GC systems
  • Low dead volume for minimal sample loss
  • Operates under high pressure up to 2000 psig
  • Wide compatibility with common analytical solvents
  • Easy visual volume reading thanks to transparent barrel
  • Ready for use in demanding laboratory environments

Technical Details

  • Nominal volume: 50 µL
  • Syringe type: Microlitre
  • Series: 700
  • Termination type: Cemented needle (N)
  • Needle gauge: 22s
  • Tip style: 2 (curved, bevelled)
  • Needle length: 51 mm
  • Fluid path materials: Stainless steel (SST), borosilicate glass
  • Autoclavable: No
  • Gas sterilisable: Yes
  • Maximum pressure rating: 2000 psig (137.9 bar)
  • Operating temperature: Min. 10 °C / Max. 50 °C
  • Barrel inner diameter: 1.03 mm
  • Outer diameter of barrel: 7.75 mm
  • Needle inner diameter: 0.15 mm
  • Outer diameter of the needle: 0.72 mm
  • Standard dead volume of the needle: 1.13 µL


Compatible Accessories

  • Adapters for connection to GC injection systems
  • Storage boxes for Hamilton syringes
  • Cleaning kits for microlitre syringes
  • Needle protective caps
  • Compatible gas sterilisation systems
  • Maintenance tools for pistons and barrels
  • Identification labels for syringes
  • Vertical storage racks for benchtops

Discover more in this category

Logistics

Remma and its partners provide you with serviced and configured equipment tailored to your needs. Receive your product at your facility with standard or express delivery, and an installation option, all through a single point of contact.

Warranty

Our 12/24-month warranty ensures the safety and reliability of your medical equipment throughout its lifespan.

Flexible Financing

Settle your medical equipment in up to 36 installments with our financing service or pay after delivery with Remma Facility.