Total Organic Carbon Analyzer TOC-VCPN

Brand: SHIMADZU

Be notified by email when the product is available
Subscribe to our partner program and become a Remma seller.


The Shimadzu TOC-VCPN is a Total Organic Carbon (TOC) analyzer designed for laboratories handling aqueous samples. Operated via PC control, it utilizes a 680 °C catalytic combustion oxidation method coupled with NDIR detection. It accurately measures Total Carbon (TC), Inorganic Carbon (IC), TOC, Non-Purgeable Organic Carbon (NPOC), and optionally Total Nitrogen (TN). Equipped with an automatic injection system, built-in dilution (factor 2 to 50), and IC pretreatment through acidification and sparging, the TOC-VCPN ensures reproducible results, a wide measurement range, and full automation for aqueous sample analysis in laboratory environments.

Description

Shimadzu TOC-VCPN: Reliable Measurements for Demanding Laboratories

The Shimadzu TOC-VCPN is a PC-controlled laboratory analyzer specifically designed for Total Organic Carbon (TOC) measurement in aqueous samples. Using high-temperature catalytic combustion at 680 °C combined with non-dispersive infrared (NDIR) detection, it accurately quantifies Total Carbon (TC), Inorganic Carbon (IC), TOC, Non-Purgeable Organic Carbon (NPOC), and optionally, Total Nitrogen (TN).

This model is ideal for environmental, pharmaceutical, industrial, and academic laboratories aiming to automate carbon analysis while ensuring high reproducibility. The TOC-VCPN offers a wide measurement range, up to 25,000 mg/L for TOC and 3,000 mg/L for IC, making it suitable for both ultra-pure water and highly contaminated samples.

The system features automatic sample injection with adjustable volumes (10 to 150 µL), internal programmable dilution (factor 2 to 50), and automated IC pretreatment through acidification and sparging. This high level of automation significantly reduces manual handling, minimizes risk of error, and ensures consistent analytical throughput.

With a rapid analysis time—approximately 3 minutes for TC and 4 minutes for IC—the TOC-VCPN allows for efficient sample batch processing, especially when paired with the ASI-V autosampler. The use of purified air as a carrier gas at 300 kPa simplifies installation, requiring no specialty gases.

The control software enables protocol customization, calibration tracking, data export, and multi-user management. This ensures full traceability and regulatory compliance in quality-controlled environments.

Compact and robust, the TOC-VCPN easily integrates into any laboratory workspace. It is a reliable choice for laboratories seeking a fully automated TOC analyzer that delivers precision, flexibility, and high performance for carbon analysis in water samples.

Features

  • Full control via an intuitive PC software interface
  • Automatic sample injection (no manual handling required)
  • Adjustable injection volume based on sample characteristics
  • Integrated IC pretreatment with automatic acidification and sparging
  • Automatic dilution function up to a 50-fold factor
  • Capable of analyzing TOC, TC, IC, NPOC (and optionally TN)
  • Automatic adjustment of analytical conditions based on detected concentration
  • Optimized separation of TC/IC steps for reduced analysis time
  • Optional module available for Total Nitrogen (TN) measurement
  • Software interface supports calibration tracking and data history
  • Result export and compatibility with standard PC printers
  • Compatible with ASI-V autosampler system
  • Compact design suitable for laboratory benchtop installation
  • Continuous system status monitoring with automatic alerts in case of anomalies

Technical Details

  • Measurement Method: Catalytic combustion oxidation at 680 °C + NDIR detection
  • Operating Mode: PC-controlled
  • Measured Parameters: TC, IC, TOC, NPOC (optional: TN)
  • Sample Type: Aqueous samples
  • TOC/TC Measurement Range: 0 to 25,000 mg/L
  • IC Measurement Range: 0 to 3,000 mg/L
  • Detection Limit: 50 µg/L
  • Reproducibility (Precision): Coefficient of variation (CV) ≤ 1.5%
  • Injection Volume: 10 to 150 µL (variable)
  • Sample Injection: Automatic
  • IC Pretreatment: Automatic internal acidification and sparging
  • Automatic Dilution: Dilution factor from 2 to 50
  • Carrier Gas: Purified air
  • Gas Pressure: 300 kPa
  • Gas Consumption: Approx. 2,210 L/month (8 h/day, 5 days/week)
  • Operating Temperature Range: 5 to 35 °C
  • Dimensions: W 440 × D 560 × H 450 mm (excluding projections)
  • Weight: Approx. 40 kg

Compatible Accessories

  • ASI-V: Multi-vial automatic sampler
  • TN Module: Enables Total Nitrogen (TN) measurement
  • Microsyringes: Replaceable according to injection volume
  • Dilution Kit: For specific application requirements
  • PC Printer: For direct result output
  • Control PC: Required for system operation

Discover more in this category

Logistics

Remma and its partners provide you with serviced and configured equipment tailored to your needs. Receive your product at your facility with standard or express delivery, and an installation option, all through a single point of contact.

Warranty

Our 12/24-month warranty ensures the safety and reliability of your medical equipment throughout its lifespan.

Flexible Financing

Settle your medical equipment in up to 36 installments with our financing service or pay after delivery with Remma Facility.