Advanced Ventilation Solutions: Discover the Puritan Bennett 840 Ventilator
The Puritan Bennett 840 ventilator is an advanced therapeutic solution designed to provide effective respiratory support and improve patients' quality of life. One of its distinctive features is Tube Compensation, which dynamically adjusts the patient's breathing effort, providing more comfortable and efficient ventilation. This feature controls the patient's carinal pressure to a constant PEEP value, optimizing ventilation and reducing the burden on the respiratory system.
Additionally, the Puritan Bennett 840 is equipped with a sophisticated Circuit Disconnect Detection system, which alerts clinicians to disconnections or obstructions in the ventilation circuit. This ensures a quick response to any interruption in the air supply, helping to prevent complications and ensure patient safety.
Another crucial aspect is the Automatic Occlusion and Patient Detection, which automatically identifies obstructions in the endotracheal or tracheal tube, as well as the absence of patient breathing. This allows for an immediate response in critical situations, such as airway obstruction, ensuring a quick and effective intervention by the medical team.
To further enhance patient safety, the Puritan Bennett 840 features an integrated Safety Net, which continuously monitors the system's operation and detects potential failures or anomalies. This ensures that any issues are identified and corrected promptly, minimizing the risk of adverse events and protecting the patient's health and well-being at all times.
The innovative design of the 840 ventilator simplifies setup and operation, reducing training requirements for your staff. Its user-friendly interface allows for easy navigation, ensuring quick and efficient use in clinical settings. Additionally, the 840 supports seamless communication with all major patient monitoring and hospital information systems, facilitating data integration and transfer for comprehensive patient care.
Featuring dual-view LCD touchscreens, the 840 ventilator displays monitored data separately from ventilator settings, providing clear and distinct information for clinicians. This dual-screen design enhances visibility and usability, allowing healthcare providers to monitor patients' status and adjust ventilation parameters with ease.
The 840 ventilator boasts extensive fleet management capabilities, catering to patients of all ages and clinical needs. Whether providing invasive ventilation or noninvasive ventilation (NIV), the 840 offers versatile and reliable respiratory support across the age spectrum. Its comprehensive features make it a valuable asset in various healthcare settings, from neonatal units to adult intensive care units.
Moreover, Covidien offers top-notch service and support for the 840 ventilator, ensuring optimal performance and reliability. With one of the most comprehensive field service programs in the ventilator industry, Covidien provides prompt maintenance, repair services, and ongoing education to healthcare professionals. The 840 ventilator is built with rugged and reliable components, featuring a modular design that allows for easy serviceability and low cost of ownership. Furthermore, it can be upgraded and customized with various software options to meet evolving clinical needs and preferences.
The Puritan Bennett 840 ventilator offers a range of advanced features to meet the diverse needs of patients and clinicians. One such feature is Proportional Assist Ventilation (PAV+), which provides tailored support for patients undergoing ventilation weaning. This innovative technology adjusts the level of assistance based on the patient's respiratory effort, promoting a smooth transition from mechanical ventilation to spontaneous breathing.
Additionally, the ventilator is equipped with BiLevel software, which enhances patient-ventilator synchrony and allows patients to breathe spontaneously at two levels of positive end-expiratory pressure (PEEP). This feature optimizes respiratory support, particularly for patients with varying ventilatory needs.
For neonatal patients, the NeoMode software offers specialized ventilation modes tailored to their unique physiological requirements. These modes ensure gentle and effective respiratory support, promoting optimal outcomes for neonatal patients.
The Volume Ventilation Plus software combines Volume Control Plus (VC+) and Pressure Regulated Volume Control (PRVC) modes to deliver precise and adaptive ventilation therapy. This feature allows clinicians to customize ventilation parameters to suit individual patient needs, ensuring optimal gas exchange and respiratory support.
Furthermore, the ventilator includes advanced clinician decision support tools such as trending software, which monitors up to 53 parameters over a 72-hour period, aiding in clinical decision-making and patient management. Respiratory mechanics software facilitates weaning readiness assessments by guiding clinicians through respiratory maneuvers, providing valuable insights into patient respiratory status.
The Tube Compensation software accurately compensates for the work of breathing associated with artificial airways, ensuring effective ventilation support without imposing additional burden on the patient. Additionally, Non-Invasive Ventilation (NIV) capabilities allow for safe and efficient ventilation across a wide range of patient populations, offering flexibility and versatility in clinical settings.
Overall, the Puritan Bennett 840 ventilator combines advanced technology with comprehensive clinical support features to deliver optimal respiratory care for patients of all ages and clinical conditions.