• Medical Imaging Medical Imaging
  • Ophtalmology Ophtalmology
  • Operating Room Operating Room
  • Anesthesia Anesthesia
  • Laboratory Laboratory
  • Dental Equipment Dental Equipment
  • Gastroenterology Gastroenterology
  • Obstetrics and Gynecology Obstetrics and Gynecology
  • Cardiology Cardiology
  • Emergency Medicine Emergency Medicine
  • Comfort and Well-being Comfort and Well-being
  • Dermatology Dermatology
  • Healthcare Furniture Healthcare Furniture
  • Urology and Nephrology Urology and Nephrology
  • ENT ENT
  • Orthopaedics Orthopaedics
  • Physical Therapy and Rehabilitation Physical Therapy and Rehabilitation
  • Sterilization Sterilization
  • Intensive Care Intensive Care
  • Surgical Instruments Surgical Instruments

Ventilator OXYLOG 1000 - Good

Brand: Dräger


The Drager Oxylog 1000 Ventilator ensures reliable emergency ventilation with advanced alarm functions for enhanced patient safety. Engineered for outdoor use, it features audible and visual alarms monitoring airway and supply pressure. Its pneumatic operation ensures uninterrupted performance, ideal for remote or challenging environments. With a supply pressure range of 2.7 to 6 bar at 60 L/min, it delivers efficient ventilation tailored to each patient. The Oxylog 1000's durability and intuitive design make it a trusted choice for emergency medical responders, providing critical care with confidence and efficiency.

Description

Drager Oxylog 1000 Ventilator: Reliable Emergency Ventilation with Advanced Alarm Functions

The Drager Oxylog 1000 Ventilator is a crucial tool for providing first aid ventilation to patients in emergency situations, particularly in outdoor environments where immediate medical attention is essential. Engineered with intuitive operation, robust construction, and unparalleled transportability, the Oxylog 1000 stands out as a comprehensive solution within its class. Whether in remote locations or challenging conditions, this ventilator is designed to perform reliably, ensuring critical care when it matters most.

One of the key features of the Oxylog 1000 is its integrated audible and visual alarms, which continuously monitor both the airway pressure and supply pressure. These alarms play a vital role in enhancing patient safety by alerting medical professionals to any deviations from optimal ventilation parameters, allowing for prompt intervention when necessary. This proactive monitoring capability provides reassurance to healthcare providers and helps maintain the highest standards of patient care, even in dynamic and unpredictable emergency situations.

An important aspect of the Oxylog 1000's design is its reliance on pneumatic operation for all functions, eliminating the need for any electrical power source. This not only enhances the ventilator's versatility but also ensures uninterrupted performance in environments where access to electricity may be limited or unavailable. As a result, medical professionals can rely on the Oxylog 1000 to deliver consistent and effective ventilation support, regardless of the circumstances they encounter during emergency missions.

Moreover, the Oxylog 1000 is built to withstand the rigors of real-world emergency response scenarios, thanks to its fundamental design and construction. From extreme temperatures to rough handling, this ventilator is engineered to maintain optimal functionality and performance, ensuring dependable operation when every second counts. Its durability and resilience make it an indispensable tool for emergency medical teams operating in diverse environments and under challenging conditions.

The Oxylog 1000 is equipped to deliver medical-grade oxygen or, in exceptional cases, compressed air, providing flexibility in resource management during emergency interventions. With a supply pressure range of 2.7 to 6 bar (40 to 88 psi) at 60 L/min, it offers reliable and efficient ventilation support tailored to the needs of each patient. This adaptability, combined with its intuitive operation and robust design, positions the Oxylog 1000 as a trusted ally for emergency medical responders, empowering them to deliver life-saving care with confidence and efficiency.

The Drager Oxylog 1000 Ventilator is equipped with advanced alarm functions designed to enhance patient safety and provide critical alerts to medical professionals during emergency ventilation procedures. These alarms serve as essential indicators, ensuring timely intervention and proactive management of ventilation parameters to optimize patient care outcomes.

One of the alarm functions of the Oxylog 1000 is the Supply Pressure Low (Psupply) alarm, which activates when the supply pressure drops below the threshold of 2.7 bar (40 psi). This alarm serves as a vital warning sign, alerting healthcare providers to potential issues with the oxygen or air supply, allowing them to take corrective action promptly to ensure uninterrupted ventilation support for the patient.

Another important alarm function is the Airway Pressure High (Paw High) alarm, which triggers when the actual airway pressure exceeds the set value (Pmax). This alarm is crucial for preventing over-pressurization of the patient's airways, which can lead to complications such as barotrauma or lung injury. By promptly notifying medical professionals of elevated airway pressure levels, this alarm enables them to adjust ventilation settings and maintain optimal pressure conditions for the patient's respiratory system.

Additionally, the Oxylog 1000 features the Airway Pressure Low (Paw Low) alarm, which activates when the airway pressure during inspiration fails to exceed a pressure of 10 mbar/cm H2O. This alarm helps ensure that adequate pressure is maintained to support effective ventilation and gas exchange in the patient's lungs. By monitoring inspiratory pressure levels, this alarm provides valuable feedback to medical teams, prompting adjustments to ventilation parameters as needed to optimize patient respiratory function.

Importantly, all alarm functions of the Oxylog 1000 are both visual and audible, providing dual modes of notification to alert medical professionals to potential issues promptly. These alarms are powered by purely pneumatic components, eliminating the need for any external power supply. This ensures that the alarms remain operational even in environments where electrical power may be limited or unavailable, allowing for seamless integration into emergency response protocols and enhancing the ventilator's reliability in critical care scenarios.

Features

    • Intuitive operation for ease of use

    • Robust construction for durability

    • Unparalleled transportability for mobility

    • Integrated audible and visual alarms for enhanced safety

    • Pneumatic operation for reliability

    • Medical-grade oxygen or compressed air supply

    • Supply pressure range of 2.7 to 6 bar (40 to 88 psi) at 60 L/min

    • Proactive monitoring of airway pressure and supply pressure

    • Alarm functions for low supply pressure, high airway pressure, and low airway pressure

    • Dual-mode notification with visual and audible alarms

Technical Details

    • Dimensions (W x H x D): 215 x 90 x 215 mm
    • Weight: 3.15 kg

Attention: For more information, please refer to the PDF file.

Compatible Accessories

Attention: For information on compatible accessories, please refer to the PDF.

Servicing and Logistics

Remma and its partners provide you with serviced and configured equipment tailored to your needs. Receive your product at your facility with standard or express delivery, and an installation option, all through a single point of contact.

Warranty

Our 12/24-month warranty ensures the safety and reliability of your medical equipment throughout its lifespan.

Flexible Financing

Settle your medical equipment in up to 36 installments with our financing service or pay after delivery with Remma Facility.