• Medical Imaging Medical Imaging
  • Ophtalmology Ophtalmology
  • Operating Room Operating Room
  • Anesthesia Anesthesia
  • Laboratory Laboratory
  • Dental Equipment Dental Equipment
  • Gastroenterology Gastroenterology
  • Obstetrics and Gynecology Obstetrics and Gynecology
  • Cardiology Cardiology
  • Emergency Medicine Emergency Medicine
  • Comfort and Well-being Comfort and Well-being
  • Dermatology Dermatology
  • Healthcare Furniture Healthcare Furniture
  • Urology and Nephrology Urology and Nephrology
  • ENT ENT
  • Orthopaedics Orthopaedics
  • Physical Therapy and Rehabilitation Physical Therapy and Rehabilitation
  • Sterilization Sterilization
  • Intensive Care Intensive Care
  • Surgical Instruments Surgical Instruments

Visual field HENSON 9000

Brand: Topcon
Categories: Ophtalmology

Be notified by email when the product is available
Subscribe to our partner program and become a Remma seller.


Henson 9000, a compact and user-friendly visual field, revolutionizes glaucoma screening and monitoring. The ZATA threshold tests enhance sensitivity, while Smart Supra screening tests ensure speed and precision. The modern and durable design seamlessly fits into your practice, featuring a comprehensive set of analytical tools and compatibility with EMRs. Since 1986, the Henson brand embodies innovation, operator efficiency, and patient comfort. With Smart Supra and ZATA, Henson 9000 delivers an intuitive user experience, enhancing operational efficiency and patient management. Choose innovation with Henson 9000.

Description

Henson 9000: Redefine Glaucoma Detection and Monitoring with Precision and Efficiency

The Henson 9000, a compact and user-friendly visual field, revolutionizes glaucoma screening and monitoring. Equipped with advanced features, it provides a comprehensive solution for healthcare professionals, combining precision, speed, and in-depth analysis.

The Henson 9000 enhances monitoring with the ZATA threshold test, incorporating patient data history and an intelligent termination criterion. This optimizes test performance and includes powerful tools for progression analysis. Smart Supra

screening tests offer speed and precision, allowing manual retesting of locations to reduce patient response errors.

The extended Smart Supra test, lasting 3.5 minutes, includes the 24-2 test with 54 points and an additional 32 points in the central 10 degrees. This improves sensitivity to detect central deficits often missed in conventional tests.

The Henson 9000 features an intuitive and ergonomic interface, facilitating integration into daily workflows. Smart Supra screening tests can be automatically extended from 30 points to 64 in case of omission, with an additional extension possible up to 86 points. This optimizes operational efficiency and reduces examination time.

With innovative visual field detection and monitoring tests, the Henson 9000 offers a complete set of analytical tools. Its compatibility with EMRs and modern design make it a versatile tool perfectly suited to healthcare professionals' practices.

Henson's History:

Professor David Henson, an innovator in the field of visual fields since 1986, founded the Henson brand on the principles of innovation, operator efficiency, and patient comfort. The launch of the CFS 2000, the first digital multi-stimulus visual field, revolutionized practices by enabling electronic result storage.

Notable Advances:

In 1993, the Helsin CFA 3000 became the first visual field to allow retesting or adding points during perimetry testing, improving specificity. In 2009, ZATA became the first

algorithm to adapt thresholds based on previous examinations, reducing test time

and making it more acceptable to patients.

Smart Supra:

Developed in response to recent research showing gaps in the 24-2 pattern, Smart Supra can extend up to 86 points, enhancing central visual field sensitivity. It offers optimized acquisition, allowing a quick test and precise mapping.

ZATA:

An intelligent alternative to SITA, ZATA uses the patient's previous data as a base. It

optimizes tests, includes intelligent termination criteria, and offers powerful progression analyses. The 24-2 test is completed in 3 minutes per eye, benefiting both practitioners and patients.

Operator Efficiency:

The intuitive interface and contextual help of the Henson 9000 facilitate users' quick

adaptation. The ability to retest points, add new locations without starting over, improves specificity, and reduces false positives.

Compact Design and Advanced Connectivity:

With its small footprint, the Henson 9000 easily adapts to different healthcare environments.

Its advanced connectivity, integrating DICOM features, Ethernet, and versatile printing options, positions it as a modern and adaptable tool.

Tests and Analytical Tools:

The Henson 9000 offers Smart Supra screening tests, ZATA threshold tests, and binocular Esterman driving tests. Results are compatible with thresholds and grayscale, providing a comprehensive analysis of total deviation and standard deviation values.

Support for Operational Efficiency:

The ability to retest and add points during the Smart Supra test reduces false positives, improving spatial mapping. Using the patient's previous data with ZATA personalizes tests, reducing anxiety and accelerating the examination.

The Henson 9000, a true innovation powerhouse, stands out as a smart choice for healthcare professionals seeking to combine performance, convenience, and precision in screening and monitoring visual field losses.

Features

    • Compact and Ergonomic Design: The HENSON 9000 stands out with its compact design, offering advanced visual solutions without compromising space.
    • Advanced Detection Technology: Equipped with advanced features, our product incorporates cutting-edge detection technology for precise and efficient glaucoma screening and monitoring.
    • ZATA Threshold Test: Enhance tracking with our ZATA threshold test, integrating patient data history for performance optimization and powerful progression analysis tools.
    • Smart Supra Screening Tests: Our Smart Supra tests offer speed and precision, reducing patient response errors and improving result reliability.
    • Improved Sensitivity: The extended Smart Supra test, with 54 points in the 24-2 test and an additional 32 points in the central 10 degrees, enhances sensitivity to detect central deficits.
    • Intuitive Interface: The user interface of the HENSON 9000 is designed to be intuitive, facilitating its smooth integration into the daily workflow of healthcare professionals.
    • Operational Efficiency: Smart Supra screening tests can be extended automatically, optimizing operational efficiency and reducing examination time.
    • In-depth Analysis of Visual Field Losses: Through innovative tests, our product provides a comprehensive set of analytical tools for in-depth analysis of visual field losses.
    • EMR Compatibility: The HENSON 9000 is compatible with Electronic Medical Records (EMR), facilitating integration into modern medical practices.
    • Modern and Versatile Design: Its modern design, coupled with advanced connectivity (DICOM, Ethernet), makes the HENSON 9000 a versatile tool suitable for various healthcare environments.
    • Innovation History: Founded by Professor David Henson, a pioneer since 1986, our product is the result of a history of constant innovation in the field of visual fields.
    • Technological Advancements: Notable advancements, such as the Helsin CFA 3000 in 1993 and the ZATA algorithm in 2009, demonstrate our commitment to continuous improvement.
    • Smart Supra and ZATA: Our Smart Supra and ZATA technologies offer rapid tests, precise mapping, and powerful analyses, benefiting both practitioners and patients.
    • Operator Efficiency: The intuitive interface and contextual assistance facilitate quick adaptation, improving specificity and reducing false positives.
    • Compact Size and Advanced Connectivity: With its compact size, the HENSON 9000 easily fits into different environments while offering advanced connectivity for modern usage.
    • Comprehensive Tests and Analysis Tools: Smart Supra screening tests, ZATA threshold tests, and binocular Esterman driving tests provide a comprehensive analysis of total deviation and standard deviation values.
    • Support for Operational Efficiency: The ability to retest and add points during the Smart Supra test reduces false positives, improving spatial mapping, and personalizing tests with ZATA.
    • Smart Choice for Healthcare Professionals: The HENSON 9000, an innovation powerhouse, is a smart choice for those seeking to combine performance, practicality, and precision in glaucoma screening and monitoring of visual field losses.

Technical Details

    • Test Features
Measurement Range: 60° (monocular) / 160° (binocular)

Test Distance: 25 cm

Maximum Stimulus Intensity: 10,000 asb

Background Illuminance: 31.4 asb

Stimulus Duration: 200 ms

Stimulus Size: Goldmann III

Stimulus Color: White

    • Standard Automated Perimetry (SAP) Test Method
Smart Supra Screening Tests - Single Stimulus: 30, 64, and 86 points tested

Smart Supra Screening Tests - Multiple Stimuli: 30, 64, and 86 points tested

Esterman (Driving Test): Groups 1 (120 points) and 2 (124 points) (EU standard)

Custom Tests: Test locations can be manually added to all Smart Supra screening tests

    • Threshold Tests/Schemes
ZATA Standard - Central Threshold: 10-48**; 24/30-2 (in complementary test)

ZATA Fast - Central Threshold: 10-48; 24/30-2 (in complementary test)

    • Average Duration*
Smart Supra Screening Tests - Single Stimulus: ~1 min (30 points); ~3.5 minutes for a complete 86-point test

Smart Supra Screening Tests - Multiple Stimuli: Less than 30 seconds (30 points)

ZATA (24-2): ~3 minutes per eye

ZATA Fast (24-2): ~2.5 minutes per eye

    • Fixation Control
Fixation Target: Single or 4-point diamond pattern

Heijl-Krakau: Yes (ZATA)

Video Eye Monitoring: Yes

    • Software Features
Patient Data Management: Compatible with MS Windows®; networks

Integration: EMR Compatibility (transmission of parameters and text files)

Hemifield Analysis: Yes

Progression Analysis: Yes

Data Import

HFA: Yes

DICOM Connectivity: Yes (images)

Ethernet: Yes, through a connected computer

Database Backup: Removable storage, network, or cloud

    • Dimensions
Weight: 13.5 kg

Size, L x W x H: 440 x 400 x 452 (mm)

Medical Device Classification: Class I Type B

Control Device: External PC / Laptop / Tablet running MS Windows® Professional, v.8 minimum

Patient Controls: C13 power input; Patient response button; 2 USB type B connectors

Electrical Requirements: 85 – 263 V AC, 50/60 Hz, 60 VA

Optional Printer: Any printer compatible with the control computer

Note: For more information, please refer to the PDF file.

Explore

Servicing and Logistics

Remma and its partners provide you with serviced and configured equipment tailored to your needs. Receive your product at your facility with standard or express delivery, and an installation option, all through a single point of contact.

Warranty

Our 12/24-month warranty ensures the safety and reliability of your medical equipment throughout its lifespan.

Flexible Financing

Settle your medical equipment in up to 36 installments with our financing service or pay after delivery with Remma Facility.